STRUCTURE AND FUNCTION Rapid Evaluation of Right and Left Ventricular Function and Mass Using Real-Time True-FISP Cine MR Imaging Without Breath-Hold: Comparison with Segmented True-FISP Cine MR Imaging with Breath-Hold

نویسندگان

  • Yoshiro Hori
  • Naoaki Yamada
  • Masahiro Higashi
  • Nobuhiko Hirai
  • Satoshi Nakatani
  • MARCEL DEKKER
چکیده

Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both realtime multislice True-FISP cine imaging without breath-hold and single-slice segmented TrueFISP cine imaging with multiple breath-holds were performed in short-axis imaging sections to encompass the entire ventricles. Vertical long-axis cine imaging using real-time True-FISP cine sequence without breath-hold was performed to evaluate heart motion during respiration in 13 subjects. Ventricular volume and mass were evaluated by four observers independently with manual tracing. Results. Real-time True-FISP cine quality was sufficient for contour detection in all 24 subjects. Cardiodynamic measurements based on real-time True-FISP cine correlated well with those based on segmented True-FISP cine [left ventricular (LV) enddiastolic volume: r 1⁄4 0:98; LV end-systolic volume: r 1⁄4 0:98; LV ejection fraction: r 1⁄4 0:91; LV mass: r 1⁄4 0:96; right ventricular (RV) end-diastolic volume: r 1⁄4 0:89; RV end-systolic volume: r 1⁄4 0:94; RV ejection fraction: r 1⁄4 0:79]. Intraand interobserver variability were sufficiently small in real-time True-FISP cine without breath-hold. Heart motion during respiration along the long axis of the left ventricle (2.2 mm to 3.7 mm) was much less than the slice interval (10 mm), confirming that misregistration of slice position during respiration was low. Conclusion. Real-time True-FISP cine without breath-hold has high reproducibility and is applicable to patients with severe cardiac dysfunction and/or arrhythmias.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular function, aortic velocity, and late gadolinium enhancement assessed by real-time and single shot CMR is comparable to breath-held segmented imaging: a prospective study

Methods Thirteen patients referred to the CMR lab for evaluation of undiagnosed cardiomyopathy were prospectively enrolled. All patients were in regular cardiac rhythm and able to breath-hold. Standard segmented k-space images (including cine, velocity mapping (VM), and late-gadolinium enhancement (LGE)) were acquired during breathhold; real-time images (including cine, VM, and LGE) were acquir...

متن کامل

University of Helsinki Report Series in Physics Hu-p-d116 Cardiac Magnetic Resonance Imaging Techniques in the Assessment of Flow and Volumetry

With ever-shortening acquisition times and electrocardiographic (ECG) gating, magnetic resonance imaging (MRI) applications have been extended to the examination of organ function. In cine cardiac MRI, heart motion can be frozen at certain phases in the cardiac cycle to obtain information on the morphology as well as functioning of the heart. Consecutive images can then be viewed dynamically to...

متن کامل

Accuracy and feasibility of a free-breathing cine technique sparsely sampled with iterative reconstruction for rapid evaluation of left ventricular function in adults and children

Background Despite being the gold standard for left ventricular function evaluation, traditional SSFP sequences still require multiple breath-holds and a relatively long scan time. This extends total duration of the exam, especially in children or adults with impaired cardiopulmonary capacity. We sought to compare a technique employing a prototype sparse sampling with iterative reconstruction (...

متن کامل

Compressed sensing reconstruction for undersampled breath-hold radial cine imaging with auxiliary free-breathing data.

PURPOSE To improve compressed sensing (CS) reconstruction of accelerated breath-hold (BH) radial cine magnetic resonance imaging (MRI) by exploiting auxiliary data acquired between different BHs. MATERIALS AND METHODS Cardiac function is usually assessed using segmented cine acquisitions over multiple BHs to cover the entire left ventricle (LV). Subjects are given a resting period between adj...

متن کامل

Free-Breathing 3D Imaging of Right Ventricular Structure and Function Using Respiratory and Cardiac Self-Gated Cine MRI

Providing a movie of the beating heart in a single prescribed plane, cine MRI has been widely used in clinical cardiac diagnosis, especially in the left ventricle (LV). Right ventricular (RV) morphology and function are also important for the diagnosis of cardiopulmonary diseases and serve as predictors for the long term outcome. The purpose of this study is to develop a self-gated free-breathi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003