Randomised experimental comparison of 23G versus 22G needle for ultrasound guided invasive fetal procedures

نویسندگان

  • R. Devlieger
  • P.N. Adama van Scheltema
  • D. Oepkes
چکیده

OBJECTIVES To experimentally compare the standard 22G spinal needle with a newer 23G needle with specific ultrasound visualisation tip (Cook echotip®, Spencer, Indiana, USA) in the setting of ultrasound-guided invasive intrauterine procedures. MATERIALS AND METHODS We first determined the size of the defects created in human fetal membranes using light microscopy and adapted area calculating software by both needles in an in vitro model performing 20 paired experiments on 4 term membrane specimens. Secondly, we determined the performance of 3 groups of operators, with different levels of experience in invasive intrauterine procedures during cordocentesis on a simulator model, using either a 22G or 23G needle. For each procedure, we measured the time required to successfully obtaining 2 ml of artificial blood in 24 paired experiments. RESULTS The mean ± SD defect sizes created was 0.66 ± 0.12 mm(2) with the 22G needle and 0.59 ± 0.13 mm(2) with the 23G needle (P = 0.11). The mean duration of sampling was 144 ± 188 sec with the 22G needle versus 140 ± 120 sec with the 23G needle (P = 0.99) for all operators pooled but four out of six operators showed shorter sampling times with a 22G needle. CONCLUSION This experimental study shows that the use of a 23G needle compared to a 22G needle was not associated with significantly different procedure duration or defect size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis

Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 ...

متن کامل

Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles

BACKGROUND Biopsy needles have recently been developed to obtain both cytological and histological specimens during endoscopic ultrasound (EUS). We conducted this study to compare 22-gauge (G) fine needle aspiration (FNA) needles, which have been the most frequently used, and new 25G fine needle biopsy (FNB) needles for EUS-guided sampling of solid pancreatic masses. METHODS We conducted a re...

متن کامل

ABG needle study: a randomised control study comparing 23G versus 25G needle success and pain scores

OBJECTIVE To determine whether a narrower gauge needle used in ABG sampling is associated with lower pain scores and complication rates without increasing the level of difficulty of the procedure. METHODS We performed a prospective single-blinded randomised control study of patients from a tertiary-level emergency department in Sydney who required an ABG analysis over the period of June 2010-...

متن کامل

Comparing endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) versus fine needle biopsy (FNB) in the diagnosis of solid lesions: study protocol for a randomized controlled trial

BACKGROUND Linear endoscopic ultrasonography (EUS) allows the visualization, identification, and characterization of the extent of lesions of the gastrointestinal (GI) tract and adjacent structures. EUS-guided fine-needle aspiration (EUS-FNA) facilitates a more accurate diagnosis of mediastinal, intra-abdominal, and pancreatic lesions through the collection of the cytological material under dir...

متن کامل

Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomised controlled trial.

AIM The aim of this study was to compare the short and long axis approaches to ultrasound guided right internal jugular vein cannulation with respect to indicators of success. METHODS Patients undergoing cardiac surgery requiring central venous cannulation (99 patients) were randomised to undergo either long or short axis ultrasound guided cannulation of the right internal jugular vein by a s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2010