Hotspots for selected metal elements and microbes accumulation and the corresponding water quality deterioration potential in an unchlorinated drinking water distribution system.

نویسندگان

  • Gang Liu
  • Yu Tao
  • Ya Zhang
  • Maarten Lut
  • Willem-Jan Knibbe
  • Paul van der Wielen
  • Wentso Liu
  • Gertjan Medema
  • Walter van der Meer
چکیده

Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This precludes an in-depth understanding of water quality deterioration and the development of proactive management strategies. The present study quantitatively evaluated the distribution of elements, ATP, Aeromonas spp., and bacterial communities in distribution pipes (PVC-U, D = 110 mm, loose deposit and biofilm niches) and household connection pipes (HDPE, D = 32 mm, HDPE biofilm niches) at ten locations in an unchlorinated distribution system. The results show that loose deposits in PVC-U pipes, acting as sinks, constitute a hotspot (highest total amount per meter pipe) for elements, ATP, and target bacteria groups (e.g., Aeromonas spp., Mycobacterium spp., and Legionella spp.). When drinking water distribution system niches with harbored elements and microbes become sources in the event of disturbances, the highest quality deterioration potential (QDP) is that of HDPE biofilm; this can be attributed to its high surface-to-volume ratio. 16s rRNA analysis demonstrates that, at the genus level, the bacterial communities in the water, loose deposits, PVC-U biofilm, and HDPE biofilm were dominated, respectively, by Polaromonas spp. (2-23%), Nitrosipra spp. (1-47%), Flavobacterium spp. (1-36%), and Flavobacterium spp. (5-67%). The combined results of elemental composition and bacterial community analyses indicate that different dominant bio-chemical processes might occur within the different niches-for example, iron-arsenic oxidizing in loose deposits, bio-calumniation in PVC-U biofilm, and methane oxidizing in HDPE biofilm. The release of 20% loose deposits, 20% PVC-U biofilm and 10% HDPE biofilm will cause significant changes of water bacterial community.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining suitable model for zoning drinking water distribution network based on corrosion potential in Sanandaj City, Iran

Corrosion in general is a complex interaction between water and metal surfaces and materials in which the water is stored or transported. Water quality monitoring in terms of corrosion and scaling is crucial, and a key element of preventive maintenance, given the economic and health hurts caused by corrosion and scaling in water utilities. The aim of this study is to determine the best model fo...

متن کامل

Evaluation of drinking water quality indices (case study: Bushehr province, Iran)

Background: Internal corrosion and the formation of scale in water distribution pipes are the most important problems for an urban water distribution system. Physical, chemical, or biological factors can lead to these two processes. Internal corrosion and scale formation can impact health, economy, and aesthetics. This study assessed the physicochemical quality parameters and evaluated the pote...

متن کامل

بررسی پتانسیل خوردگی و رسوب گذاری آب شرب شبکه توزیع شهر کرمان

  Background : Occurrence of corrosion and deposition in drinking water in distribution system can leads to economic and health damages. The aim of this study was to investigate the corrosion and precipitation potential of drinking water in Kerman distribution system.   Methods : This cross-sectional study was performed from September to November of 2011. For determining the chemical quality of...

متن کامل

Determination of corrosion and sedimentation potential in drinking water distribution system of khorramabad city by corrosion indices and weight loss method

Pirialam R1, Shams khorramabadi Gh2, Shahmansouri MR3, Farzadkiya M4 1. MSc in Environmental Health, Lorestan University of Medical Sciences, Khorramabad, Iran 2. Assistant Professor, Department of Environmental Health, Faculty of Health, Lorestan University of Medical Sciences, Khorramabad, Iran 3. Associate Professor, Department of Environmental Health, Faculty of Health, Isfahan University o...

متن کامل

Pyrosequence analysis of the hsp65 genes of nontuberculous mycobacterium communities in unchlorinated drinking water in the Netherlands.

Studies have shown that certain opportunistic pathogenic species of nontuberculous mycobacteria (NTM) can be present in distributed drinking water. However, detailed information about NTM population composition in drinking water is lacking. Therefore, NTM communities in unchlorinated drinking water from the distribution system of five treatment plants in the Netherlands were characterized using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water research

دوره 124  شماره 

صفحات  -

تاریخ انتشار 2017