Human temporal bones versus mechanical model to evaluate three middle ear transducers.
نویسندگان
چکیده
A life-size mechanical middle ear model and human temporal bones were used to evaluate three different middle ear transducers for implantable hearing aids: the driving rod transducer (DRT), the floating mass transducer (FMT) or vibrant sound bridge, and the contactless transducer (CLT). Results of the experiments with the mechanical model were within the range of the results for human temporal bones. However, results with the mechanical model showed better reproducibility. The handling of the mechanical model was considerably simpler and less time-consuming. Systematic variations of mounting parameters showed that the angle of the rod has virtually no effect on the output of the DRT, the mass loading on the cable of the FMT has a larger impact on the output than does the tightness of crimping, and the output level of the CLT can be increased by 10 dB by optimizing the mounting parameters.
منابع مشابه
Morphology and morphometrical study of hamster middle ear bones
The objective of the current study was to determine the anatomical features of the auditory ossicles inhamster. Twenty temporal bones from 10 adult hamsters, weighing 275-300 g were used. After dissectingthem, the features of the ossicles were assessed with an ocular micrometer and photographed by astereomicroscope. Finally, all data were evaluated and analysed using the Sigma Statt software. T...
متن کاملA fossil stapes from Sterkfontein, South Africa, and the hearing capabilities of early hominids.
The three small bones of the human middle ear—the malleus, incus and stapes—have been the subject of research since the mid fifteenth century (Arensburg et al., 1981). Consequently, knowledge of their anatomy and embryology is extensive (e.g. Schuknecht & Gulya, 1986; McPhee & Van de Water, 1988). Middle ear bones have also been well studied in other extant primates and in Neanderthals (e.g., M...
متن کاملRound window membrane implantation with an active middle ear implant: a study of the effects on the performance of round window exposure and transducer tip diameter in human cadaveric temporal bones.
OBJECTIVES To assess the importance of 2 variables, transducer tip diameter and resection of the round window (RW) niche, affecting the optimization of the mechanical stimulation of the RW membrane with an active middle ear implant (AMEI). MATERIALS AND METHODS Ten temporal bones were prepared with combined atticotomy and facial recess approach to expose the RW. An AMEI stimulated the RW with...
متن کاملComputer-integrated finite element modeling of human middle ear.
The objective of this study was to produce an improved finite element (FE) model of the human middle ear and to compare the model with human data. We began with a systematic and accurate geometric modeling technique for reconstructing the middle ear from serial sections of a freshly frozen temporal bone. A geometric model of a human middle ear was constructed in a computer-aided design (CAD) en...
متن کاملThe Influence of Incudostapedial Joint Separation on the Middle Ear Transfer Function
OBJECTIVES One of the risks in middle ear surgery is high frequency hearing loss. It is believed that manipulations on the middle ear ossicles with the instruments may cause overstimulation of the inner ear and damage of the hear cells. Controversy arises whether temporary separation of the ossicles has any impact on middle ear transfer function and hearing threshold after surgery. The aim of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 44 3 شماره
صفحات -