Calculation of the clearance requirements for the development of a hemodialysis-based wearable artificial kidney.

نویسندگان

  • Dong Ki Kim
  • Jung Chan Lee
  • Hajeong Lee
  • Kwon Wook Joo
  • Kook-Hwan Oh
  • Yon Su Kim
  • Hyung-Jin Yoon
  • Hee Chan Kim
چکیده

Wearable artificial kidney (WAK) has been considered an alternative to standard hemodialysis (HD) for many years. Although various novel WAK systems have been recently developed for use in clinical applications, the target performance or standard dose of dialysis has not yet been determined. To calculate the appropriate clearance for a HD-based WAK system for the treatment of patients with end-stage renal disease with various dialysis conditions, a classic variable-volume two-compartment kinetic model was used to simulate an anuric patient with variable target time-averaged creatinine concentration (TAC), daily water intake volume, daily dialysis pause time, and patient body weight. A 70-kg anuric patient with a HD-based WAK system operating for 24 h required dialysis clearances of creatinine of at least 100, 50, and 25 mL/min to achieve TACs of 1.0, 2.0, and 4.0 mg/dL, respectively. The daily water intake volume did not affect the clearance required for dialysis under various conditions. As the pause time per day for the dialysis increased, higher dialysis clearances were required to maintain the target TAC. The present study provided theoretical dialysis doses for an HD-based WAK system to achieve various target TACs through relevant mathematical kinetic modeling. The theoretical results may contribute to the determination of the technical specifications required for the development of a WAK system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Requirements for Designing a Wearable Smart Blanket System for Monitoring Patients in Ambulance

Introduction: Nowadays, smart systems and advanced tools such as wearable systems have grown significantly in order to monitor patients and keep their condition under control. The aim of this study was to determine the requirements for designing a wearable smart blanket system (WSBS) to monitor patients in ambulance instantaneously. Method: After reviewing the characteristics of wearable system...

متن کامل

Requirements for Designing a Wearable Smart Blanket System for Monitoring Patients in Ambulance

Introduction: Nowadays, smart systems and advanced tools such as wearable systems have grown significantly in order to monitor patients and keep their condition under control. The aim of this study was to determine the requirements for designing a wearable smart blanket system (WSBS) to monitor patients in ambulance instantaneously. Method: After reviewing the characteristics of wearable system...

متن کامل

A wearable artificial kidney for patients with end-stage renal disease.

BACKGROUND Stationary hemodialysis machines hinder mobility and limit activities of daily life during dialysis treatments. New hemodialysis technologies are needed to improve patient autonomy and enhance quality of life. METHODS We conducted a FDA-approved human trial of a wearable artificial kidney, a miniaturized, wearable hemodialysis machine, based on dialysate-regenerating sorbent techno...

متن کامل

A Proposed Peritoneal-Based Wearable Artificial Kidney.

Ideally, an artificial kidney should simulate the normal kidney in providing continuous metabolic control, removal of toxins, and unrestricted patient freedom. Of the dialysis procedures available, continuous ambulatory peritoneal dialysis (CAPD) comes the closest to this ideal but provides inadequate dialysis and fails to remove protein-bound toxins. A continuous, wearable, peritoneal-based ar...

متن کامل

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hemodialysis international. International Symposium on Home Hemodialysis

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 2016