[Purpose] The fluid goniometer is an instrument for measuring range of motion. Reliability of the fluid goniometer has not been established for subjects with painful knee joints. The purpose of this study was to determine the inter-rater and intra-rater reliability of the fluid goniometer in measuring active knee flexion of painful knees and to test its agreement with the gold standard ruler goniometer. [Subjects and Methods] Twenty-five individuals with either unilateral or bilateral painful knees participated in the study. Two raters each took three measurements with the same Baseline® fluid goniometer on 35 knees. [Results] Intraclass correlation coefficients (ICC) were 0.97 for both intra-rater and inter-rater measurements, denoting high relative reliability. The large standard error of measurement (SEM) value of 6.6 degrees, and the 95% limits of agreement, which revealed a potential difference of 18.4 degrees between raters of similar subjects, however, revealed poor absolute reliability. The smallest detectable difference (SDD) of 18 degrees was also large. [Conclusion] The results revealed excellent relative reliability, but a large amount of variability between the raters' measurements. The sensitivity of the fluid level of the goniometer to end range tremors of the lower leg flexed against gravity in the obligatory prone position may contribute significantly to the large variability in knee ROM values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of radiographic measurements of knee motion following knee arthroplasty for use in a virtual knee clinic

INTRODUCTION We sought to validate radiographic measurements of range of motion of the knee after arthroplasty as part of a new system of virtual clinics. METHODS The range of motion of 52 knees in 45 patients was obtained by 2 clinicians using standardised techniques and goniometers. Inter-rater reliability and intraclass correlation coefficients (ICCs) were calculated. Radiographs of these...

متن کامل

Reliability of Body Landmarks Analyzer for Measuring the Quadriceps Angle

Genovarum and Genovalgum are the most common postural deformities of the knee joint. A quadriceps angle is used to measure these anomalies. Methods of measuring this angle are divided into two categories: invasive and non-invasive. The purpose of the present research was to study the inter/intra rater reliability of the non-invasive Body Landmarks Analyzer method for measuring of the quadriceps...

متن کامل

Validity and reliability of using photography for measuring knee range of motion: a methodological study

BACKGROUND The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measurin...

متن کامل

Evaluation of Spasticity Using the Ashworth Scale with Intermediate Scores (ASIS)

Objectives: The main purpose of this research was to study and contribute to an accurate test of spastic limb. The intra, inter rater reliability of the test was examined. Methods: The present study was carried out in two parts In the first part of the study, the modified Ashworth Scale with Intermediate Scores (ASIS) was studied. During the second part of the study the intra, inter rater re...

متن کامل

Inter-rater reliability for measurement of passive physiological movements in lower extremity joints is generally low: a systematic review.

QUESTION What is the inter-rater reliability for measurements of passive physiological or accessory movements in lower extremity joints? DESIGN Systematic review of studies of inter-rater reliability. PARTICIPANTS Individuals with and without lower extremity disorders. OUTCOME MEASURES Range of motion and end-feel using methods feasible in daily practice. RESULTS 17 studies were include...