Airway ultrasound to detect endotracheal tube cuff herniation

نویسندگان

  • Debendra Kumar Tripathy
  • R Ravindra Bhat
  • Sangeeta Dhanger
چکیده

Endotracheal tube (ETT) cuff herniation is not an uncommon event in Intensive Care Units and operating rooms. The cause for this can be displacement of the tube or overinflation of ETT cuff.[1] Usually, it is noticed by the sound of gas leaking around the tube or when there is a fall in tidal volume and end-tidal carbon dioxide (CO2). Confirmation and repositioning of the ETT require direct laryngoscopy which has disadvantages such as stress response[2] and is difficult to perform intra-operatively, particularly if the patient is not in supine position. We report a case of ETT cuff herniation from glottis which was detected with the use of ultrasound.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review

Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...

متن کامل

Ventilation difficulty due to herniation of inflating tube of the cuff inside the endotracheal tube.

The complications due to airway equipments remain to be one of the most challenging situations for the anesthesiologists. Any part of an endotracheal tube may cause a risk when it leads to an obstruction in the airway. Here, we present an increased airway pressure due to herniation of inflating tube of the cuff inside an armored (wire reinforced) endotracheal tube during neurosurgery in prone p...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

A comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.

Cuffed endotracheal tubes are one aspect of airway management designed to ensure safety, yet patients can be at risk for injury from underinflated and overinflated endotracheal cuffs. Tracheal pressures exceeding approximately 48 cm H2O impede capillary blood flow, potentially causing tracheal damage, and pressures below approximately 18 mm Hg may increase the risk of aspiration. There is no st...

متن کامل

Clinical benefits of visualization of airway anatomy and manipulation of the endotracheal tube cuff with the GlideScope in the morbidly obese patient during tracheotomy.

Inadvertent deflation of the endotracheal tube cuff during a tracheotomy can complicate the surgical procedure, especially in a morbidly obese patient. Also, the anesthesia provider may lose control of the airway, with the inability to reintubate in case of airway edema, airway secretions, or airway fire. The use of the GlideScope video laryngoscope (Verathon Inc, Bothell, Washington) in the mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 61  شماره 

صفحات  -

تاریخ انتشار 2017