Effectiveness of a novel gas‐release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy

نویسندگان

  • Landon S. Wootton
  • Rajat J. Kudchadker
  • A. Sam Beddar
  • Andrew K. Lee
چکیده

Endorectal balloons (ERBs) are routinely used in prostate proton radiation therapy to immobilize the prostate and spare the rectal wall. Rectal gas can distend the rectum and displace the prostate even in the presence of ERBs. The purpose of this work was to quantify the effects an ERB with a passive gas release conduit had on the incidence of rectal gas. Fifteen patients who were treated with a standard ERB and 15 with a gas-release ERB were selected for this retrospective study. Location and cross-sectional area of gas pockets and the fraction of time they occurred on 1133 lateral kilovoltage (kV) images were analyzed. Gas locations were classified as trapped between the ERB and anterior rectal wall, between the ERB and posterior rectal wall, or superior to the ERB. For patients using the standard ERB, gas was found in at least one region in 45.8% of fractions. Gas was trapped in the anterior region in 37.1% of fractions, in the posterior region in 5.0% of fractions, and in the sigmoid region in 9.6% of fractions. For patients using the ERB with the gas-release conduit, gas was found in at least one region in 19.7% of fractions. Gas was trapped in the anterior region in 5.6% of fractions, in the posterior region in 8.3% of fractions, and in the sigmoid region in 7.4% of fractions. Both the number of fractions with gas in the anterior region and the number of fractions with gas in at least one region were significantly higher in the former group than in the latter. The cross-sectional area of trapped gas did not differ between the two groups. Thus gas-release balloon can effectively release gas, and may be able to improve clinical workflow by reducing the need for catheterization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rectal dose-volume differences using proton radiotherapy and a rectal balloon or water alone for the treatment of prostate cancer.

PURPOSE To describe dose-volume values with the use of water alone vs. a rectal balloon (RB) for the treatment of prostate cancer with proton therapy. MATERIALS AND METHODS We analyzed 30 proton plans for 15 patients who underwent CT and MRI scans with an RB or water alone. Simulation was performed with a modified MRI endorectal coil and an RB with 100 mL of water or water alone. Doses of 78-...

متن کامل

A comparison between hydrogel spacer and endorectal balloon: An analysis of intrafraction prostate motion during proton therapy

The purpose of this study was to evaluate intrafraction prostate motion in patients treated with proton therapy and an endorectal balloon or a hydrogel spacer using orthogonal x-rays acquired before and after each treatment field. This study evaluated 10 patients (662 fields throughout treatment) treated daily with an endorectal balloon (ERB) and 16 patients (840 fields throughout treatment) tr...

متن کامل

SU-E-T-289: Scintillating Fiber Based In-Vivo Dose Monitoring System to the Rectum in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation.

PURPOSE To construct a dose monitoring system based on an endorectal balloon coupled to thin scintillating fibers to study the dose delivered to the rectum during prostate cancer proton therapy METHODS: The Geant4 Monte Carlo toolkit version 9.6p02 was used to simulate prostate cancer proton therapy treatments of an endorectal balloon (for immobilization of a 2.9 cm diameter prostate gland) and...

متن کامل

Real‐time in vivo dosimetry for SBRT prostate treatment using plastic scintillating dosimetry embedded in a rectal balloon: a case study

A novel FDA approved in vivo dosimetry device system using plastic scintillating detectors placed in an endorectal balloon to provide real-time in vivo dosimetry for prostatic rectal interface was tested for use with stereotactic body radiotherapy (SBRT). The system was used for the first time ever to measure dose during linear accelerator based SBRT. A single patient was treated with a total d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012