A Low Capacitance Cascaded H-bridge 7-level Statcom

نویسندگان

  • J. Gunasekaran
  • S. Rajesh Kumar
چکیده

This paper introduces a cascaded H -bridge multilevel converter (CHB-MC) based StatCom system that is able to operate with extremely low dc capacitance values. The theoretical limit is calculated for the maximum capacitor voltage ripple, and hence minimum dc capacitance values that can be used in the converter. The proposed lowcapacitance StatCom (LC-StatCom) is able to operate with large capacitor voltage ripples, which are very close to the calculated theoretical maximum voltage ripple. The maximum voltage stress on the semiconductors in the LC-StatCom is lower than in a conventional StatCom system. The variable cluster voltage magnitude in the LC-StatCom system drops well below the maximum grid voltage, which allows a fixed maximum voltage on the individual capacitors. It is demonstrated that the proposed LC-StatCom has an asymmetric V-I characteristic, which is especially suited for operation as a reactive power source within the capacitive region. A high-bandwidth control system is designed for the proposed StatCom to provide control of the capacitor voltages during highly dynamic transient events. The proposed LC-StatCom system is experimentally verified on a low-voltage 7level CHB-MC prototype. The experimental results show successful operation of the system with ripples as high as 90% of the nominal dc voltage. The required energy storage for the LC-StatCom system shows significant reduction compared to a conventional StatCom

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation

In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...

متن کامل

Control Scheme of Multi Level Cascaded H - Bridge STATCOM

This paper presents a control scheme of cascaded H-bridge STATCOM in three-phase power systems. Cascaded H-bridge STATCOM has merits in point of switching losses, output harmonics, and the number of circuit components. But every H-bridge cell has isolated dc capacitors. So the balancing problem of capacitor voltages exists. Since STATCOM is often requested to operate under asymmetrical conditio...

متن کامل

An Advanced Multilevel Cascaded H-Bridge Based Statcom with Power Quality Enhancement

Fig. 1.1 Shows the circuit configuration for a 19-level (lineto-neutral) H-bridge StatCom (H-StatCom). Each stack ofH-bridges essentially forms one phase of a threephase currentcontrolledvoltage source. The purpose of the H-StatCom isto modulate the voltage at the output of each stack so thatthe current through the inductors can be controlled to providepower factor correction, compensate for sy...

متن کامل

Selective Harmonics Elimination Technique in Cascaded H-Bridge Multi-Level Inverters Using the Salp Swarm Optimization Algorithm

A new optimization method is proposed in this paper for finding the firing angles in multi-level voltage source inverters to eliminate low-order selective harmonics and reduce total harmonic distortion (THD) value of the output voltage. For thid end, Fourier series is used for calculating objective function and selecting specific harmonics. Regarding the nature and complexity of the employed no...

متن کامل

Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter

This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-P...