Experimental validation of a pulse wave propagation model for predicting hemodynamics after vascular access surgery.
نویسندگان
چکیده
Hemodialysis patients require a vascular access that is, preferably, surgically created by connecting an artery and vein in the arm, i.e. an arteriovenous fistula (AVF). The site for AVF creation is chosen by the surgeon based on preoperative diagnostics, but AVFs are still compromised by flow-associated complications. Previously, it was shown that a computational 1D-model is able to describe pressure and flow after AVF surgery. However, predicted flows differed from measurements in 4/10 patients. Differences can be attributed to inaccuracies in Doppler measurements and input data, to neglecting physiological mechanisms or to an incomplete physical description of the pulse wave propagation after AVF surgery. The physical description can be checked by validating against an experimental setup consisting of silicone tubes mimicking the aorta and arm vasculature both before and after AVF surgery, which is the aim of the current study. In such an analysis, the output uncertainty resulting from measurement uncertainty in model input should be quantified. The computational model was fed by geometrical and mechanical properties collected from the setup. Pressure and flow waveforms were simulated and compared with experimental waveforms. The precision of the simulations was determined by performing a Monte Carlo study. It was concluded that the computational model was able to simulate mean pressures and flows accurately, whereas simulated waveforms were less attenuated than experimental ones, likely resulting from neglecting viscoelasticity. Furthermore, it was found that in the analysis output uncertainties, resulting from input uncertainties, cannot be neglected and should thus be considered.
منابع مشابه
A pulse wave propagation model to support decision-making in vascular access planning in the clinic.
The preferred vascular access for hemodialysis is an autologous arteriovenous fistula (AVF) in the arm: a surgically created connection between an artery and vein. The surgeon selects the AVF location based on experience and preoperative diagnostics. However, 20-50% of all lower arm AVFs are hampered by a too low access flow, whereas complications associated with too high flows are observed in ...
متن کاملA sensitivity analysis of a personalized pulse wave propagation model for arteriovenous fistula surgery. Part B: Identification of possible generic model parameters.
Decision-making in vascular access surgery for hemodialysis can be supported by a pulse wave propagation model that is able to simulate pressure and flow changes induced by the creation of a vascular access. To personalize such a model, patient-specific input parameters should be chosen. However, the number of input parameters that can be measured in clinical routine is limited. Besides, patien...
متن کاملValidation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients.
Vascular access dysfunction is one of the main causes of morbidity and hospitalization in hemodialysis patients. This major clinical problem points out the need for prediction of hemodynamic changes induced by vascular access surgery. Here we reviewed the potential of a patient-specific computational vascular network model that includes vessel wall remodeling to predict blood flow change within...
متن کاملFluid-structure interaction simulations of hemodynamics in mice: applications to hypertension research
Motivation Arterial stiffening is both cause and consequence of hypertension,currently the main cause of death in Europe. Hemodynamic metrics such as central pulse pressure (cPP) and pulse wave velocity, which can be non invasively measured, are now known as important predictive factors of diseases and diseases susceptibility. Computational Fluid Dymanic techniques enable an accurate representa...
متن کاملPlane Wave Propagation Through a Planer Slab
An approximation technique is considered for computing transmission and reflection coefficients for propagation of an elastic pulse through a planar slab of finite width. The propagation of elastic pulse through a planar slab is derived from first principles using straightforward time-dependent method. The paper ends with calculations of enhancement factor for the elastic plane wave and it is s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 45 9 شماره
صفحات -
تاریخ انتشار 2012