A method for repositioning of stereotactic brain patients with the aid of real-time CT image guidance.
نویسندگان
چکیده
This note presents a method that recalculates the coordinates of the isocentre for patients undergoing stereotactic radiotherapy to the brain with a relocatable head frame based on a pre-treatment CT scan. The method was evaluated by comparing initial stereotactic coordinates of the isocentre with the recalculated coordinates for eight single-fraction patients. These patients had the Brown-Roberts-Wells (BRW) frame fixed to the outer table of the skull, and therefore the coordinates of any anatomical point should be identical between the initial scan and the pre-treatment scan. The differences between the two sets of coordinates were attributed to errors in the method. The results showed that the systematic errors in the recalculated coordinates were less than 0.05 mm, and they were not statistically significant. The random errors (one standard deviation) were from 0.35 mm (lateral) to 0.58 mm (vertical). The average value of the combined 3D difference was 0.75 mm.
منابع مشابه
Principles of Neuronavigation
Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...
متن کاملGenerating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method
Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملنقش تکنولوژی در بهبود درمان سرطان
One major strategy, technology-driven improvement of treatment conformity in cancer treatment, including advanced image guidance, advanced charged particle therapy (CPT), and application of nanoparticles in hyperthermia, will enable further widening of the therapeutic window of cancer treatment in the era of precision medicine. The state of the art treatment in photon-therapy is advanced 3D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 50 16 شماره
صفحات -
تاریخ انتشار 2005