Poly(ethylene glycol)-based biosensor chip to study heparin-protein interactions.
نویسندگان
چکیده
a Departments of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, NY 12180, USA b Divisions of Medicinal and Natural Products Chemistry, University of Iowa, Iowa City, IA 52212, USA c Department of Biology, Rensselaer Polytechnic Institute, Troy, NY 12180, USA d Department of Pediatrics, College of Medicine, University of Arkansas, Little Rock, AR 72202, USA e Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
منابع مشابه
Signal amplification of target protein on heparin glycan microarray.
A heparin glycan chip (HepGlyChip) with a 4800-fold enhanced signal-to-noise ratio as compared with the control without heparin was developed for high-throughput analysis of heparin-protein interactions for new drug development and for screening biological samples in diagnostic applications. As a proof of concept, a heparin glycan microarray was prepared on a poly(styrene-co-maleic anhydride) (...
متن کاملSOI optical microring resonator with poly(ethylene glycol) polymer brush for label-free biosensor applications.
Label-free monitoring of biomolecular interactions has become of key importance for the emerging proteomics field. Monitoring real time interaction kinetics and high throughput screening of complex samples is of major importance for a variety of applications. We previously reported the use of Silicon-on-Insulator photonics microring resonators for cheap disposable biosensors on chip. Silicon ph...
متن کاملImmobilization of RNase S-Peptide on a single-stranded DNA-fixed gold surface and effective masking of its surface by an acridinyl poly(ethylene glycol).
Oligonucleotide-peptide conjugate was synthesized by coupling of RNase S-peptide to a 24-mer single-stranded DNA (ssDNA) oligonucleotide to be immobilized on its complementary ssDNA oligonucleotide-fixed gold surface of sensor chip or electrode. Immobilization of on the ssDNA-fixed gold surface through DNA duplex formation was confirmed by quartz crystal microbalance (QCM) and electrochemical m...
متن کاملStudy of Surface Tension of Binary Mixtures of Poly (Ethylene Glycol) in Water and Poly (Propylene Glycol) in Ethanol and its Modeling Using Neural Network
متن کامل
Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
An analytical method is presented, combining novel microcontact imprinting technique and capacitive biosensor technology for the detection of BSA. Glass cover slips were used for preparation of protein stamps. The microcontact-BSA imprinted gold electrodes were prepared in the presence of methacrylic acid (MAA) and poly-ethylene glycol dimethacrylate (PEGDMA) as the cross-linker by bringing the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical biochemistry
دوره 343 1 شماره
صفحات -
تاریخ انتشار 2005