Comparison of a new procalcitonin assay from roche with the established method on the brahms kryptor.

نویسندگان

  • Holger K de Wolf
  • Jacqueline Klein Gunnewiek
  • Yvonne Berk
  • Jody van den Ouweland
  • Menno de Metz
چکیده

Procalcitonin (PCT) is a 13-kDa peptide and a precursor of calcitonin. In a healthy population, PCT concentrations are negligible (1 ). In systemic bacterial and fungal infections, plasma concentrations are raised, whereas concentrations remain fairly low in infections of viral or nonspecific cause (2 ). Recent studies have demonstrated the potential of PCT as a parameter to guide antibiotic therapy in different groups of patients, i.e., patients with chronic obstructive pulmonary disease experiencing respiratory tract infections (3, 4 ). The most frequently used medical decision points at which the use of antibiotic therapy is considered are 0.25 g/L and 0.50 g/L, depending on the patient population (3, 4 ). The first PCT assays were based on manual immunochemistry methods (Brahms PCT LIA). These assays have been replaced by fully automated immunochemistry methods (Brahms Kryptor, Brahms LIAISON, Olympus SphereLight 180). Recently, the PCT assay has been modified for use on a consolidated routine immunochemistry analyzer, the Roche Modular E170 system. We evaluated the analytical performance of this new assay by following the EP10 protocol, a document from the Clinical and Laboratory Standards Institute to test precision, linearity, recovery, carryover, and drift. Samples were prepared at different concentrations, from 0.24 –2.85 g/L. Three aliquots of each concentration were assayed on 5 different days, in a specific assay order. The within-run CV ranged from 3.0% for the lowest concentration to 1.3% for the highest concentration. The between-day CV ranged from 6.3% for the lowest concentration to 2.8% for the highest. These levels of imprecision were comparable with those reported for the PCT assay on the Brahms Kryptor (5 ). The mean recovery was 99%. There was no evidence of nonlinearity or sample carryover. The limit of quantification, i.e., the lowest concentration of analyte that can be quantified with a between-run imprecision of 20%, met the manufacturer’s specification of 0.06 g/L. In addition, we compared the new PCT assay from Roche on the Modular 170 with the widely accepted PCT assay from Brahms on the Kryptor (5 ). For analytical comparison, we used 229 samples of patient serum obtained from 195 different patients who were admitted to our hospital for lower respiratory tract infections (81, exacerbation of chronic obstructive pulmonary disease; 114, pneumonia). The patients participated in an ongoing study in our hospital on the etiology of exacerbations of chronic obstructive pulmonary disease, a study approved by the local ethics committee. Samples were also collected from 34 patients after antibiotic treatment. The majority of the serum samples were obtained within 24 h of admission. Samples not immediately analyzed were stored at 80 °C until analysis. PCT concentrations ranged from 0.02 g/L (limit of detection, i.e., the lowest concentra-

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter comparison of automated procalcitonin immunoassays

OBJECTIVES A multicenter study to compare results of BRAHMS Kryptor PCT with those obtained using four BRAHMS-partnered procalcitonin (PCT) automated immunoassays (DiaSorin Liaison, BioMérieux Vidas, Roche Cobas E601 and Siemens Advia Centaur) and the Diazyme immunotubidimetric assay implemented on four clinical chemistry platforms (Abbott Architect c16000, Siemens Advia 2400, Roche Cobas C501 ...

متن کامل

The Comparison of the Point-of-Care Serum Procalcitonin Assay Method with the BRAHMS Certified Method

Background and Aims: As a method for the diagnosis and management of sepsis, the serum procalcitonin assay is routinely used, especially in the emergency department (ED) and intensive care units (ICU). Procalcitonin has reasonable diagnostic accuracy for bacteremia in hospitalized patients of all age groups with suspected infection or sepsis. This study aimed to compare the Getein Biotech proca...

متن کامل

Comparison of a New Procalcitonin Assay from Roche with the Established Method on the Brahms Kryptor

Procalcitonin (PCT) is a 13-kDa peptide and a precursor of calcitonin. In a healthy population, PCT concentrations are negligible (1 ). In systemic bacterial and fungal infections, plasma concentrations are raised, whereas concentrations remain fairly low in infections of viral or nonspecific cause (2 ). Recent studies have demonstrated the potential of PCT as a parameter to guide antibiotic th...

متن کامل

A new sensitive automated assay for procalcitonin detection: LIAISON® BRAHMS PCT® II GEN

OBJECTIVES To assess the performance of LIAISON® BRAHMS PCT® II GEN (DiaSorin, Saluggia, Italy) in procalcitonin (PCT) determination by comparing it to the assay reference method B·R·A·H·M·S PCT KRYPTOR (Thermo Fisher Scientific Clinical Diagnostics, Hennigsdorf, Germany) and assessing its ability to discriminate between healthy subjects and patients with suspected infection. METHODS Diagnost...

متن کامل

A new sensitive automated assay for procalcitonin detection: LIAISON

Objectives: To assess the performance of LIAISON s BRAHMS PCT s II GEN (DiaSorin, Saluggia, Italy) in procalcitonin (PCT) determination by comparing it to the assay reference method B R A H M S PCT KRYPTOR (Thermo Fisher Scientific Clinical Diagnostics, Hennigsdorf, Germany) and assessing its ability to discriminate between healthy subjects and patients with suspected infection. Methods: Diagno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2009