The design and analysis of a homeotic response element

نویسندگان

  • Robert A.H. White
  • Simon E. Aspland
  • Jenny J. Brookman
  • Lesley Clayton
  • Graham Sproat
چکیده

We have shown that the 26 bp bx1 element from the regulatory region of Distal-less is capable of imposing control by the homeotic genes Ultrabithorax and abdominal-A on a general epidermal activator in Drosophila. This provides us with an assay to analyze the sequence requirements for specific repression by these Hox genes. Both the core Hox binding site, 5'-TAAT, and the adjacent EXD 5'-TGAT core site are required for repression by Ultrabithorax and abdominal-A. The Distal-less bx1 site thus fits with the model of Hox protein binding specificity based on the consensus PBX/HOX-family site TGATNNAT[g/t][g/a], where the key elements of binding specificity are proposed to lie in the two base pairs following the TGAT. A single base pair deletion in the bx1 sequence generates a site, bx1:A(-)mut, that on the consensus PBX/HOX model would be expected to be regulated by the Deformed Hox gene. We observed, however, that the bx1:A(-)mut site was regulated predominantly by Sex combs reduced, Ultrabithorax and abdominal-A. The analysis of this site indicates that the specificity of action of Hox proteins may depend not only on selective DNA binding but also on specific post-binding interactions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Strain Inhomogeneity in Vortex Extrusion using Finite Element Method and Response Surface Methodology

The effect of geometrical parameters involved in vortex extrusion (VE) die design, on AA1050 aluminium alloy processed by VE were investigated using finite element analysis (FEA) and response surface methodology (RSM). For this, VE die length (L), reduction in area (RA), twist angle , and position of control points in Beziers' formulation (C1) were considered as input parameters and strain inho...

متن کامل

PARAMETRIC STUDY ON RAILWAY FASTENING SYSTEM RESPONSE SUBJECTED TO DIFFERENT AXLE LOAD

There are several factors causing fastening systems to deteriorate faster than the designed life. The high repetitive loads from a moving train being one of the main factors, track irregularities, design and installation defects of track components, non-uniform rail support stiffness, unevenness in the rail seat deterioration are some of the factors causing fastenings systems to deteriorate fas...

متن کامل

Proposed Relationship to Design the Waffle Floor under Harmonic Vertical Loading

The design codes of building are mainly related to the strength of the building and there are no specific codes for the design of building with waffle floors for vibration sensitive equipment. The finite element model, ANSYS, is capable to consider the effects of floor thickness, the size of the bays and stiffness of the columns for analyzing the vibration of the waffle floors and vibration tra...

متن کامل

New Design of Mems piezoresistive pressure sensor

The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 „m length and with thickness=400 µm is studied. The electric response of this microsensor is obtained with applyi...

متن کامل

Multi-response Optimization of Grooved Circular Tubes Filled with Polyurethane Foam as Energy Absorber

The main objective of this research is to improvethe design and performance of the polyurethane foam-filled thin-walled aluminum grooved circular tubes using multi-response optimization (MRO) technique. The tubes are shaped with the inner and the outer circular grooves at different positions along the axis. For this aim, several numerical simulations using ABAQUS finite element explicit code ar...

متن کامل

Response Modification Factor of Chevron Braced Frame With Pall Friction Damper

Response modification factors (R-factor) are used in current seismic building codes to reduce earthquake forces associated with seismic design level to determine force levels. In recent years, many authors have shown great interest in the development of seismic structural systems and several theoretical and experimental studies have been conducted to investigate performance of dampers but littl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Mechanisms of Development

دوره 91  شماره 

صفحات  -

تاریخ انتشار 2000