Implantable collamer posterior chamber intraocular lenses: a review of potential complications.

نویسندگان

  • Paulo Fernandes
  • José M González-Méijome
  • David Madrid-Costa
  • Teresa Ferrer-Blasco
  • Jorge Jorge
  • Robert Montés-Micó
چکیده

PURPOSE To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported complications using the latest ICL designs. RESULTS Cataract was the major postoperative complication reported: 136 (5.2%) in 2592 eyes. Of those, 43.4% (n=59) were reported within 1 year, 15.4% (n=21) between 1 and 3 years, and 35.3% (n=48) ≥ 3 years after ICL implantation. Twenty-one (15.4%) cataracts were reported as surgically induced, 46 (33.8%) eyes had poor vault (<200 μm), and cataract surgery was carried out in 27.9% (n=38) of eyes. Early acute intraocular pressure increase was also reported to be relatively frequent, whereas acute pupillary block was less frequent and mostly resolved with additional iridotomies. A total of 42 ICLs were explanted due to cataract and IOP. Reported endothelial cell loss varied from 9.9% at 2 years to 3.7% 4 years postoperatively. This loss was reported to be more pronounced within the first 1 to 2 years, with stability or lower progression after that time. CONCLUSIONS The majority of reported complications after ICL implantation are cataract formation. The improvements in lens geometry and more accurate nomograms applied to the selection of the lens to be implanted, in addition to the surgeon's learning curve, might be factors in the decreased occurrence of postoperative complications reported currently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior Chamber Toric Implantable Collamer Lenses – Literature Review

Posterior Chamber Phakic Toric Implantable Collamer Lenses have become increasingly used to correct refractive error associated with astigmatism. These devices are claimed to provide high efficacy in terms of refractive correction. This book chapter is an updated review on the safety and effectiveness and potential complications of the toric implantable collamer lens (Toric ICL) published in pe...

متن کامل

Evaluation of Phakic Posterior Chamber Intraocular Implantable Contact Lens for High Myopia

Purpose: To evaluate efficacy, predictability and safety of the surgical correction of high myopia using the phakic posterior chamber implantable collamer lens. Design: A prospective, nonrandomized, non-comparative interventional case series. Participants: Twenty seven eyes of fifteen patients aged from 20 to 46 years having high myopia were included. Intervention: STAAR modified collamer impla...

متن کامل

Implantation of an implantable collamer lens and iris cerclage for the treatment of Urrets-Zavalia syndrome

A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic intraocular lens implantation in her left eye under local anesthesia and with no intraoperative complications. The preoperative slit-lamp examination was normal, and she had no relevant past medical history. On the second postoperative day, patient developed fixed, dilated mydriasis, and one month later, an IOL...

متن کامل

JOURNAL OF MEDICAL CASE REPORTS Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

Introduction: We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation: A 53-year-old woman had undergone toric implan...

متن کامل

Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

INTRODUCTION We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. CASE PRESENTATION A 53-year-old woman had undergone toric implan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 27 10  شماره 

صفحات  -

تاریخ انتشار 2011