Non-Contact Cardiac Activity Monitoring using Pulsed Laser Vibrometer

نویسندگان

  • Chen Chia WANG
  • Sudhir TRIVEDI
  • Susan KUTCHER
  • Feng JIN
  • Narasimha S. PRASAD
چکیده

We demonstrate experimentally the detection of detailed human cardiac mechanical activity in a remote, non-contacting, and non-ionizing manner using a pulsed laser vibrometer. The highly sensitive pulsed laser vibrometer allows the detection of the temporally-phased mechanical events occurring in individual cardiac cycles even from the surface of clothing-covered extremities of the subjects. Fine structures of the detected cardiac traces are identified with their meanings assigned and corroborated using accelerometer and electrocardiogram measurements obtained concurrently with the pulsed laser vibrometer studies. Copyright © 2014 IFSA Publishing, S. L.

منابع مشابه

Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design

This research integrated a MEMS electrostatic driven micro-probe and a laser Doppler vibrometer for non-contact vibration mode scanning probe microscope system design. The microprobe tip was placed in perpendicular to the sample surface, and the built-in capacitor on the microprobe was excited to vibrate by a sinusoidal drive voltage to generate Coulomb electrostatic force. The applied frequenc...

متن کامل

Non-destructive acoustic defect detection in drug tablets.

For physical defect detection in drug tablets, a non-destructive and non-contact technique based on air coupled excitation and interferometric detection is presented. Physical properties and mechanical integrity of drug tablets can often affect their therapeutic and structural functions. The monitoring for defects and the characterization of tablet mechanical properties therefore have been of p...

متن کامل

Design and Application of a Photoacoustic Sensor for Monitoring the Laser Generated Stress Waves in Optical Fiber

Measurement of stress transients generated by a 400ns pulsed HF laser in an infrared fluoride glass fiber has been made using fast time – response piezoelectric film transducer. Acoustic signals up to 12 mV with frequencies ranging in megahertz generated by 21 mJ laser pulse when passed through the fiber axis in the linear region. It is shown that useful information such as onset of non - linea...

متن کامل

An experimental study of winding vibration of a single-phase power transformer using a laser Doppler vibrometer ¬リニ

Transformer tank vibration has been used for the condition monitoring and fault diagnosis of power transformers, as well as for the evaluation of radiated sound power from such power transformers. In both applications, seeking a correlation between transformer tank vibration and the vibration of the transformer windings and core becomes a challenge for fault identification and noise control at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014