7. Measurement of mass attenuation coefficients by Si(Li), NaI(Tl) and Cd(Tl) detectors

نویسندگان

  • Turgay Korkut
  • Mustafa Recep Kaçal
  • İbrahim Han
  • Ferdi Akman
چکیده

Mass attenuation coefficients of the some elements were determined for two photon energies using different three detectors. The samples were irradiated using 10 mCi Cd-109 and 100 mCi Am-241 radioactive point sources. The photons were separately counted by Si(Li), NaI(Tl) and Cd(Tl) detectors. It was observed that the mass attenuation coefficient decreases with increasing energy and increases with increasing atomic number. The measured values are compared with the theoretical ones calculated using WinXcom program.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

Radiation attenuation of boron doped clay for 662, 1173 and 1332 keV gamma rays

Background: Radiation shielding properties is an important for a material wish can be used the photon attenuation coefficients of clay produced using different rate of boron have been measured for the purpose of radioactive waste disposal. Materials and Methods: The measurement has been performed using gamma spectrometer contains NaI (Tl) detector at the photon energies of 662, 1173 an...

متن کامل

Evaluation of Pixelated NaI(Tl) Detectors for PET

A new detector design using pixelated NaI(Tl) crystals has been evaluated for use in positron emission tomography (PET). This detector uses 4 4 30 mm NaI(Tl) pixels coupled via a lightguide (1.4 cm thick) to an array of 39 mm diameter photomultiplier tubes (PMTs) in an Anger detector design. Our measurements show that the high light output of NaI(Tl) leads to a good discrimination of the 4 mm N...

متن کامل

Determination of mass attenuation coefficients for concretes containing tincal concentrator waste

This study is concerned with the use of the concrete samples produced by tincal concentrator waste as a gamma radiation shield. The values of mass attenuation coefficients for concrete samples measured at 59.54 (Am-241) and 80.99 (Ba-133) keV photon energies. Gamma rays were counted by a NaI(Tl) detector coupled to multi channel analyzer (MCA) using narrow beam transmission arrangement. Theoret...

متن کامل

Determination of Full Energy Peak Efficiency of NaI(Tl) Detector Depending on Efficiency Transfer Principle for Conversion Form Experimental Values

In this work we calibrated the NaI(Tl) scintillation detectors (5.08 × 5.08 cm and 7.62 × 7.62 cm) and the Full Energy Peak Efficiency (FEPE) for these detectors have been calculated for point sources placed at different positions on the detector axis using the analytical approach of the effective solid angle ratio. This approach is based on the direct mathematical method reported by Selim and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012