Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
نویسندگان
چکیده
BACKGROUND T1 mapping is widely used today in CMR, however, it underestimates true T1 values and its measurement error is influenced by several acquisition parameters. The purpose of this study was the extraction of accurate T1 data through the utilization of comprehensive, parallel Simulations for QUAntifying RElaxation Magnetic Resonance constants (SQUAREMR) of the MOLLI pulse sequence on a large population of spins with physiologically relevant tissue relaxation constants. METHODS A CMR protocol consisting of different MOLLI schemes was performed on phantoms and healthy human volunteers. For every MOLLI experiment, the identical pulse sequence was simulated for a large range of physiological combinations of relaxation constants, resulting in a database of all possible outcomes. The unknown relaxation constants were then determined by finding the simulated signals in the database that produced the least squared difference to the measured signal intensities. RESULTS SQUAREMR demonstrated improvement of accuracy in phantom studies and consistent mean T1 values and consistent variance across the different MOLLI schemes in humans. This was true even for tissues with long T1s and MOLLI schemes with no pause between modified-Look-Locker experiments. CONCLUSIONS SQUAREMR enables quantification of T1 data obtained by existing clinical pulse sequences. SQUAREMR allows for correction of quantitative CMR data that have already been acquired whereas it is expected that SQUAREMR may improve data consistency and advance quantitative MR across imaging centers, vendors and experimental configurations. While this study is focused on a MOLLI-based T1-mapping technique, it could however be extended in other types of quantitative MRI throughout the body.
منابع مشابه
Effect of supplemental oxygen on native blood and myocardial MOLLI T1 relaxation times
Background Magnetic resonance (MR) T1 relaxation time measurements are increasingly used for myocardial tissue characterization. Significant differences in native and gadolinium-enhanced measurements have been associated with ischemic and non-ischemic cardiomyopathies, myocardial fat deposition, fibrosis and edema as well as regional and global ventricular functional parameters. Supplemental ox...
متن کاملT1-mapping in the heart: accuracy and precision
The longitudinal relaxation time constant (T1) of the myocardium is altered in various disease states due to increased water content or other changes to the local molecular environment. Changes in both native T1 and T1 following administration of gadolinium (Gd) based contrast agents are considered important biomarkers and multiple methods have been suggested for quantifying myocardial T1 in vi...
متن کاملFree-breathing multislice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence.
PURPOSE To develop a novel pulse sequence for free-breathing, multislice, native myocardial T1 mapping. METHODS The slice-interleaved T1 (STONE) sequence consists of multiple sets of single-shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudin...
متن کاملSimultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
BACKGROUND Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this paper we present and evaluate a novel method for 3D interleaved T1 and T2 mapping of the whole le...
متن کاملComparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
BACKGROUND T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different sequences head to head however are sparse. METHODS We compared three T1 mapping sequences, ShMO...
متن کامل