Testing Spatial Detection and Light Sensitivity in Homonymous Hemianopia by Rarebit and Conventional Automated Perimetry
نویسندگان
چکیده
Purpose of the study was to compare Rarebit Perimetry (RP) with Standard Automatic Perimetry (SAP) in patients with ischemic retrochiasmal lesions. Seventeen patients with homonymous hemianopia underwent SAP and RP. Correlation between the two techniques was evaluated, congruent defects were quantified in the spared hemifield and residual vision areas were investigated in the blind hemifield. A strong correlation was found between SAP and RP. In the spared hemifield, RP detected congruent defects in a higher percentage of cases. Residual detection function has been found at RP in 69,2 % of perimetrically blind visual field quadrants as assessed by SAP. In conclusion, RP appears to be useful to assess visual function in hemianopic patients. As compared to SAP, it seems able to detect small congruent defects in a higher percentage of cases. Finally, a certain residual function seems to be present at RP in the blind regions of the visual field, however, for this finding further demonstrations are required.
منابع مشابه
CASE SERIES Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Ophthalmoscope Retinal Perimetry
Sparing or partial recovery of visual fields in hemianopic patients is frequently difficult to document. This is because when testing large field losses, the standard automated or manual visual field testing systems have limited fixation controls. Measured visual field recovery in these cases may not be real but instead may be due to an artifact such as scanning eye movement. This article illus...
متن کاملA comparison between Humphrey and frequency doubling perimetry for chiasmal visual field defects.
PURPOSE To evaluate and compare the diagnostic ability of frequency doubling technology perimetry (FDT) with standard automated perimetry (SAP) using Humphrey Field Analyser for the detection of visual field defects produced by chiasmal lesions. METHODS Fifteen patients with documented chiasmal disease and previously diagnosed of bitemporal hemianopia with Humphrey perimetry were prospectivel...
متن کاملScanning eye movements in homonymous hemianopia documented by scanning laser ophthalmoscope retinal perimetry.
Sparing or partial recovery of visual fields in hemianopic patients is frequently difficult to document. This is because when testing large field losses, the standard automated or manual visual field testing systems have limited fixation controls. Measured visual field recovery in these cases may not be real but instead may be due to an artifact such as scanning eye movement. This article illus...
متن کاملSensitivity and specificity of frequency doubling perimetry in neuro-ophthalmic disorders: a comparison with conventional automated perimetry.
PURPOSE Frequency-doubling technology (FDT) perimetry was developed as a screening test for glaucoma. Patients with damage to the neuro-ophthalmic sensory visual pathways have different patterns of visual loss than patients with glaucoma. The current study was designed to determine the sensitivity and specificity of FDT as a screening test, compared with conventional automated perimetry (CAP) i...
متن کاملA new visual field test in empty sella syndrome: rarebit perimetry.
PURPOSE Several visual field defects can be seen in empty sella syndrome (ESS). In this study, the authors aimed to evaluate the visual field defects in patients with ESS by rarebit perimetry and to compare the results with Humphrey perimetry. METHODS Left eyes of 13 patients with ESS and left eyes of 15 age-matched normal subjects were included in the study. Visual field testing was performe...
متن کامل