Applications of Flexible Ultrasonic Transducer Array for Defect Detection at 150 °C

نویسندگان

  • Jeanne-Louise Shih
  • Kuo-Ting Wu
  • Cheng-Kuei Jen
  • Chun-Hsiung Chiu
  • Jing-Chi Tzeng
  • Jiunn-Woei Liaw
چکیده

In this study, the feasibility of using a one dimensional 16-element flexible ultrasonic transducer (FUT) array for nondestructive testing at 150 °C is demonstrated. The FUT arrays were made by a sol-gel sprayed piezoelectric film technology; a PZT composite film was sprayed on a titanium foil of 75 µm thickness. Since the FUT array is flexible, it was attached to a steel pipe with an outer diameter of 89 mm and a wall thickness of 6.5 mm at 150 °C. Using the ultrasonic pulse-echo mode, pipe thickness measurements could be performed. Moreover, using the ultrasonic pulse-echo and pitch-catch modes of each element of FUT array, the defect detection was performed on an Al alloy block of 30 mm thickness with a side-drilled hole (SDH) of f3 mm at 150 °C. In addition, a post-processing algorithm based on the total focusing method was used to process the full matrix of these A-scan signals of each single transmitter and multi-receivers, and then the phase-array image was obtained to indicate this defect- SDH. Both results show the capability of FUT array being operated at 150 °C for the corrosion and defect detections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

The study of phased-ultrasonic receiving-planar array transducer for PD location in power transformer

Partial discharge (PD) is the main cause of electric equipment degradation. PD location can provide the scientific direction and analysis for equipment condition monitoring. The phased-ultrasonic receiving-planar array transducer for PD location in transformer is studied in this paper. The operation environment and material properties of transducer are analyzed. The center frequency of transduc...

متن کامل

An Ultrasonic System for the Inspection of Components with Irregular Geometry Using a Flexible Phased Array Contact Transducer and Related Processing Algorithms

The primary and secondary cooling systems of French pressurized water reactor contain many welded components with complex geometry : elbows, welding without smooth profile, nozzles. In service inspections of such components performed with conventional ultrasonic (US) contact transducers present limited performances. First, variations in sensitivity, due to unmatched contact on depressions or ir...

متن کامل

High Temperature Flexible Ultrasonic Transducers for Structural Health Monitoring and Ndt

Flexible ultrasonic transducers (FUTs) consisting of a 75 μm thick metal membrane, a piezoelectric composite with a thickness larger than 85 μm and a top electrode were developed for structural health monitoring (SHM) and non-destructive testing (NDT) applications. The piezoelectric films were made by a sol-gel spray technique. Its ultrasonic performance in terms of signal strength is at least ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2013