Multicomponent quantification of Astragalus residue fermentation liquor using ion chromatography-integrated pulsed amperometric detection

نویسندگان

  • Ying Zhang
  • Jiarong Wu
  • Quanhui Ni
  • Hong Dong
چکیده

Chinese medicine residues contain abundant cellulose and hemicellulose, which are potential renewable carbon sources for ethanol production. The aim of the present study was to develop a rapid and reliable method to evaluate the cellulose and hemicellulose utilization in Chinese medicine residues. In the present study, key hydrolysates (arabinose, galactose, glucose, xylose, and cellobiose) of the cellulose and hemicellulose in fermentation liquor of Astragalus residues were simultaneously quantified by ion chromatography using an integrated pulsed amperometric detector (IPAD). HPLC analysis was performed on a Dionex ICS-2500 equipped with GP50 gradient pump and ED50 IPAD. The working and reference electrodes were gold electrode and Ag/AgCl electrode, respectively. Separation was achieved on serial no. 002627 Dionex Analytical column (2×250 mm). Sodium hydroxide of 250 mM and water were used as the mobile phase with a flow rate of 0.2 ml/min. The temperature of column was kept at 30°C. This method was validated for accuracy and precision. The regression equation revealed a good linear relationship (R2=0.9959-0.9984) within the test ranges. The limits of detection and quantification for five standard analytes (arabinose, galactose, glucose, xylose and cellobiose) were in the range of 0.067-0.091 and 0.08-0.23 mg/l, respectively. The method showed good reproducibility for the quantification of five analytes in fermentation liquor of Astragalus residue with intra-and inter-day variations less than 3.843%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of biogenic amines in alcoholic beverages by ion chromatography with suppressed conductivity detection and integrated pulsed amperometric detection.

The determination of biogenic amines in alcoholic beverages is important to assess the potential risks associated with the consumption of high concentrations of these compounds. In addition, product storage conditions and the length of storage can cause the formation of biogenic amines that reduce product quality. We report a new method using cation-exchange chromatography with either suppresse...

متن کامل

Simultaneous Separation and Quantification of Linear Xylo- and Cello-Oligosaccharides Mixtures in Lignocellulosics Processing Products on High- Performance Anion-Exchange Chromatography Coupled with Pulsed Amperometric Detection

A simple one-step method was developed for rapid separation and quantification of the linear xylo-oligosaccharides (XOS) and cellooligosaccharides (COS) mixtures by using high-performance anionexchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD). By exploiting small ion-exchange behavioral differences of various oligosaccharide components on the CarboPac PA200 column, ...

متن کامل

Quantitation of digitoxin, digoxin, and their metabolites by high-performance liquid chromatography using pulsed amperometric detection

A novel detection method for the cardiac glycosides digitoxin, digoxin, and their metabolites is described. Both isocratic and gradient water-acetonitrile elutions were employed with an octadecylsilane column. The effluent was monitored by integrated pulsed amperometry in an alkaline medium (pH> 12) by adding sodium hydroxide post-column. Using isocratic elution, peak responses were linear from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017