Meta-Analysis of Randomized Controlled Trials Comparing EX-PRESS Implantation with Trabeculectomy for Open-Angle Glaucoma

نویسندگان

  • Wei Wang
  • Xiulan Zhang
چکیده

PURPOSE To evaluate the efficacy and safety of EX-PRESS implantation compared with trabeculectomy for uncontrolled open-angle glaucoma. METHODS Pertinent randomized controlled trials were identified through systematic searches of the PubMed, EMBASE, and Cochrane Library. The efficacy measures utilized were the weighted mean differences (WMDs) for the intraocular pressure reduction (IOPR), the reduction in glaucoma medications, the change of visual acuity, and the relative risks (RRs) for operative success rates. The safety measures utilized were RRs for postoperative complications. The pooled effects were calculated using the random-effects model. RESULTS Four randomized controlled trials of 292 eyes were included in this meta-analysis. The WMDs of the IOPR comparing the EX-PRESS with trabeculectomy were -0.25 (95% Cl: -3.61 to 3.11) at 6 month, 0.053 (-4.31 to 4.42) at 12 months, 0.81 (-4.06 to 5.67) at 24 months, and 0.20 (-2.11 to 2.51) at final follow-up. There was no statistically significance for IOPR at any point after surgery. There were also no significant differences in the reduction in glaucoma medications or visual acuity between the groups. The pooled relative risks comparing EX-PRESS with Trabeculectomy were 1.36 (1.11 to 1.66) for the complete operative success rate and 1.05 (0.94 to 1.17) for the qualified operative success rate. EX-PRESS and Trabeculectomy were associated with similar incidences in most complications with the exception of hyphema, with pooled RR being 0.18 (0.046 to 0.66). CONCLUSIONS EX-PRESS implantation and trabeculectomy have similar efficacy in IOP-lowering, medication reduction, vision recovery, and qualified operative success rates. EX-PRESS associated with higher rates of complete operative success and fewer hyphema than with Trabeculectomy. However, these should be interpreted with caution because of the inherent limitations of the included studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ex-PRESS Implantation versus Trabeculectomy in Open-Angle Glaucoma: A Meta-Analysis of Randomized Controlled Clinical Trials

OBJECTIVE To evaluate the efficacy and safety of Ex-PRESS implantation (Ex-PRESS) compared to trabeculectomy in the treatment of patients with open-angle glaucoma (OAG). METHODS A comprehensive literature search using the Cochrane Methodology Register to identify randomized controlled clinical trials (RCCTs) comparing Ex-PRESS to trabeculectomy in patients with OAG. Efficacy estimates were me...

متن کامل

Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma

BACKGROUND This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. METHODS Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS glaucoma filtration device or underwent a trabeculectomy were followed for up...

متن کامل

Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis

OBJECTIVE To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measur...

متن کامل

Randomized Clinical Trial for Early Postoperative Complications of Ex-PRESS Implantation versus Trabeculectomy: Complications Postoperatively of Ex-PRESS versus Trabeculectomy Study (CPETS)

We compared early postoperative complications between trabeculectomy and Ex-PRESS implantation. Enrolled patients with 39 primary open-angle or 25 exfoliative glaucoma were randomly assigned to receive trabeculectomy (trabeculectomy group) or Ex-PRESS implantation (Ex-PRESS group). Primary outcomes were early postoperative complications, including postoperative anterior chamber inflammation, fr...

متن کامل

EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability

Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014