Patients after atrial switch operation for transposition of the great arteries can not increase stroke volume under dobutamine stress as opposed to patients with congenitally corrected transposition.
نویسندگان
چکیده
BACKGROUND Patients after atrial switch operation for transposition of the great arteries have limited exercise performance. Rigid atrial baffles may cause a relative preload reduction. Previous studies have had suboptimal control groups, which ideally should consist of patients with congenitally corrected transposition of the great arteries (ccTGA) without previous heart surgery, having a systemic right ventricle, but lacking rigid atrial baffles. Therefore the aim of this study was to test the impact of atrial baffles by comparing 12 atrial switch patients with 11 ccTGA patients. METHODS AND RESULTS Systemic right ventricular stroke volume (SV), heart rate, cardiac index, and other parameters were assessed during rest and dobutamine stress magnetic resonance imaging. The most important difference between the groups was that the atrial switch patients could not increase SV during stress, whereas ccTGA patients increased it significantly. There was no difference between groups in the rise of the cardiac index. Heart rate increased significantly more in atrial switch patients than in ccTGA patients. CONCLUSIONS The results support the hypothesis that atrial baffles restrict a rise in SV under dobutamine stress in patients after atrial switch operation for transposition of the great arteries.
منابع مشابه
Heart transplantation in atrial switch and in congenitally corrected transposition of the great arteries
Background Patients with congenitally corrected transposition of the great arteries (ccTGA) and those who underwent atrial switch eventually face systemic ventricular failure due to deterioration of the morphological and structural function. Heart transplantation is at present one of the two best available options. We report our institutional experience of heart transplantation in this group, w...
متن کاملLong-term prognosis of double-switch operation for congenitally corrected transposition of the great arteries.
OBJECTIVES Recently, the double-switch operation for congenitally corrected transposition of the great arteries has become the procedure of choice in our institute; however, the long-term follow-up is uncertain. METHODS From 1983 to 2010, 90 patients with congenitally corrected transposition of the great arteries underwent the double-switch operation, which comprised of an atrial switch plus ...
متن کاملRole of volume loading in left ventricular training.
and overview. Circulation 2006;114:1645–53. [19] Du ZD, Hijazi ZM, Kleinman CS, Silverman NH, Larntz K. Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. J Am Coll Cardiol 2002;39:1836–44. [20] Van De Bruaene A, DeMP, Buys R, Vanhees L, Delcroix M, Voigt JU et al. Right ventricular load an...
متن کاملClinical Outcomes after Anatomic Repair Including Hemi-Mustard Operation in Patients with Congenitally Corrected Transposition of the Great Arteries
BACKGROUND AND OBJECTIVES The aims of this study were to determine the early and late outcomes of anatomic repair of congenitally corrected transposition of the great arteries (ccTGA) and to evaluate effectiveness of the hemi-Mustard procedure. SUBJECTS AND METHODS We conducted a retrospective, single-center study of patients who underwent anatomic repair for ccTGA between July 1996 and Decem...
متن کاملسپتوستومی دهلیزی با راهنمایی اکوکاردیوگرافی: گزارش هشت بیمار
Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. Howeve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 72 7 شماره
صفحات -
تاریخ انتشار 2008