Adaptation and evaluation of a chromogenic test procedure for fibrin monomers on a centrifugal analyzer.
نویسنده
چکیده
We evaluated a recently introduced quantitative chromogenic substrate test for the determination of fibrin monomers in plasma (Coa-set FM test). The sample and reagent volume, the reaction time and the composition of the zero standard were modified. In its optimized form the test showed good reproducibility and an acceptable linearity range. Freezing and thawing of the samples does not cause problems. The coefficient of correlation in the comparison of the Coa-set FM test and the Boehringer FM test was r = 0.967, whereas the conformity was poor. The reference ranges for males and females were not significantly different, resulting in a universal reference range of 8.4-13.2 nmol/l. In conclusion, the Coa-set FM test is, in the modified form, a precise, quick and sensitive method, which can become a valuable tool in the early detection of circulating fibrin monomers.
منابع مشابه
Evaluation of a fully automated centrifugal analyzer for performance of hemostasis tests.
We have evaluated the performance of a centrifugal analyzer, specifically designed for hemostasis tests, for methods based on clotting time as measured by light scattering, or based on splitting of chromogenic substrates. The results were compared with those obtained with a semiautomated coagulometer (clotting tests) or with a manually operated photometer (chromogenic tests). In general, the re...
متن کاملKinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.
We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-starch technique. The method for total amylase appeared to be rapid and precise (C...
متن کاملRapid enzymatic determination of amylase in serum and urine using a centrifugal analyzer.
A convenient, totally enzymatic procedure for amylase assay using a centrifugal analyzer is described. The reaction scheme is examined using both starch and maltotetroase as substrates. Data for the reaction kinetics, linearity and sensitivity are presented. The proposed method exhibits linear reaction kinetics between three and five minutes after the initiation of the reaction and is linear to...
متن کاملAdaptation of a NADH-linked serum 5'-nucleotidase procedure to a small benchtop centrifugal analyzer.
متن کامل
In vitro evaluation of decontamination effects on mechanical properties of fibrin membrane
Background: Tissue engineering has been investigated as a potential method for healing traumatized tissues. Biomaterials are material devices or implants used to repair or replace native body tissues and organs. The present study was conducted to evaluate the effects of decontamination methods on biological/mechanical properties and degradation/adhesion test of the platelet‑-rich fibrin (PRF) m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie
دوره 28 3 شماره
صفحات -
تاریخ انتشار 1990