Total hip replacement: A meta-analysis to evaluate survival of cemented, cementless and hybrid implants

نویسندگان

  • Phedy Phedy
  • H Dilogo Ismail
  • Charles Hoo
  • Yoshi P Djaja
چکیده

AIM To determine whether cemented, cementless, or hybrid implant was superior to the other in terms of survival rate. METHODS Systematic searches across MEDLINE, CINAHL, and Cochrane that compared cemented, cementless and hybrid total hip replacement (THR) were performed. Two independent reviewers evaluated the risk ratios of revision due to any cause, aseptic loosening, infection, and dislocation rate of each implants with a pre-determined form. The risk ratios were pooled separately for clinical trials, cohorts and registers before pooled altogether using fixed-effect model. Meta-regressions were performed to identify the source of heterogeneity. Funnel plots were analyzed. RESULTS Twenty-seven studies comprising 5 clinical trials, 9 cohorts, and 13 registers fulfilled the research criteria and analyzed. Compared to cementless THR, cemented THR have pooled RR of 0.47 (95%CI: 0.45-0.48), 0.9 (0.84-0.95), 1.29 (1.06-1.57) and 0.69 (0.6-0.79) for revision due to any reason, revision due to aseptic loosening, revision due to infection, and dislocation respectively. Compared to hybrid THR, the pooled RRs of cemented THR were 0.82 (0.76-0.89), 2.65 (1.14-6.17), 0.98 (0.7-1.38), and 0.67 (0.57-0.79) respectively. Compared to hybrid THR, cementless THR had RRs of 0.7 (0.65-0.75), 0.85 (0.49-1.5), 1.47 (0.93-2.34) and 1.13 (0.98-1.3). CONCLUSION Despite the limitations in this study, there was some tendency that cemented fixation was still superior than other types of fixation in terms of implant survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Total hip replacement in patients with ankylosing spondylitis.].

The authors present their experience with total hip replacement in patients with ankylosing spondylitis. In the period of 1985-1997 they performed in total 66 total hip replacements in 41 patients. Of the total number of the used implants 24 were fully cemented (the average follow-up - 13 years), 3 were hybrid and 39 cementless (the average follow-up - 6 years). The results of total hip replace...

متن کامل

Results of 3,668 primary total hip replacements

BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...

متن کامل

Have cementless and resurfacing components improved the medium-term results of hip replacement for patients under 60 years of age?

BACKGROUND AND PURPOSE The optimal hip replacement for young patients remains unknown. We compared patient-reported outcome measures (PROMs), revision risk, and implant costs over a range of hip replacements. METHODS We included hip replacements for osteoarthritis in patients under 60 years of age performed between 2003 and 2010 using the commonest brand of cemented, cementless, hybrid, or re...

متن کامل

Comparison of cementless and hybrid cemented total knee arthroplasty.

Cementless total knee arthroplasty (TKA) implants were designed to provide long-term fixation without the risk of cement-associated complications. The purpose of this study was to evaluate the outcome of titanium-coated cementless implants compared with hybrid TKA implants with a cemented tibial and a cementless femoral component. The authors performed a case-control, single-center study of 120...

متن کامل

A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement. Ten-year survival analysis.

We have carried out a long-term survival analysis of a prospective, randomised trial comparing cemented with cementless fixation of press-fit condylar primary total knee replacements. A consecutive series of 501 replacements received either cemented (219 patients, 277 implants) or cementless (177 patients, 224 implants) fixation. The patients were contacted at a mean follow-up of 7.4 years (2.7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017