Determination of sixteen UV filters in suncare formulations by high-performance liquid chromatography.

نویسندگان

  • D J Schakel
  • D Kalsbeek
  • K Boer
چکیده

Reversed-phase liquid chromatography (RP-LC) with UV detection was developed for the simultaneous determination of 16 organic UV filters worldwide authorized in suncare products. The filters determined were: 4-aminobenzoic acid, homosalate, benzophenone-3,2-phenylbenzimidazole-5-sulfonic acid, terephthalidene dicamphor sulfonic acid, 4-tert-butyl-4'-methoxy-dibenzoylmethane, octocrylene, 2-ethylhexyl-4-methoxycinnamate, isoamyl-p-methoxycinnamate, ethylhexyltriazone, drometrizole trisiloxane, diethylhexyl butamido triazone, 3-(4-methylbenzyliden) camphor, 2-ethylhexylsalicylate, 2-ethylhexyl-4-dimethylaminobenzoate and benzophenone-4. A C18 stationary phase and a gradient of ethanol-aqueous acetate buffer containing 0.2 mM of EDTA, was used with a flow-rate of 1.0 ml/min. UV detection was carried out at 313 and 360 nm. The analysis required 32 min and the limits of detection were between 30 and 4130 mg/kg in the original suncare product. Tween 80 was used to break down the different emulsions in order to procure a proper extraction of the UV filters. The method was validated for UV filters in three matrices, oil, water-in-oil emulsion and oil-in-water emulsion. Recoveries from spiked samples were 86-113% depending on the matrix used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design

this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...

متن کامل

A Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design

this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1049 1-2  شماره 

صفحات  -

تاریخ انتشار 2004