Verification of a near-field error sensor placement method in active control of compact noise sources.

نویسندگان

  • Benjamin M Shafer
  • Kent L Gee
  • Scott D Sommerfeldt
چکیده

Recent experiments in active noise control (ANC) have used near-field error sensors whose locations are determined according to the minimization of sound power. Sensors should be placed in regions where the sound pressure reductions are the greatest during sound power minimization of the ANC system. Near-field pressure measurements of noise sources with and without ANC were made. With the error sensors in theoretically ideal locations, the measured near-field pressure map approximates the theoretical map created under the condition of minimized radiated power. Moving the error sensors to theoretically nonideal locations greatly reduces the attenuation of radiated sound power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of theoretical modeling to multichannel active control of cooling fan noise.

Multichannel active control has been applied to the global reduction of tonal noise from a cooling fan. In order to achieve consistent far-field attenuation of multiple harmonics of the blade passage frequency (BPF) of the fan, an analytical model has been applied to the control system in order to determine appropriate transducer configurations. The results of the modeling show that the additio...

متن کامل

Session 1pEAa: Active and Passive Control of Fan Noise 1pEAa1. Active control of axial and centrifugal fan noise

Both axial and centrifugal fans are used to cool information technology (IT) equipment. These fans generate noise that can be annoying to their users, particularly the tonal noise that can be radiated. Work has focused on developing a method to attenuate the tonal noise associated with both of these types of fans. A compact system is used, whereby control sources are placed in close proximity t...

متن کامل

Improving 3-D Imaging Breast Cancer Diagnosis Systems Using a New Method for Placement of Near-Infrared Sources and Detectors

The objective of this research was to improve 3-D imaging system by near-infrared light emission in breast tissue to achieve a more accurate diagnosis of tumor. The results of repeated experiments in this research have shown that with this imaging system, a more accurate diagnosis of abnormal area depends on the location of the sources and detectors. Therefore, an optimal location model has bee...

متن کامل

OPTIMAL SENSOR PLACEMENT FOR DAMAGE DETECTION BASED ON A NEW GEOMETRICAL VIEWPOINT

In this study, efficient methods for optimal sensor placement (OSP) based on a new geometrical viewpoint for damage detection in structures is presented. The purpose is to minimize the effects of noise on the damage detection process. In the geometrical viewpoint, a sensor location is equivalent to projecting the elliptical noise on to a face of response space which is corresponding to the sens...

متن کامل

Active noise control of enclosed centrifugal blowers

Global active noise control has been obtained on the tonal noise from a small centrifugal blower, similar to those used in laptop computers. Compact control systems were investigated for two configurations. The blower was mounted in both a short rectangular duct and in a mock laptop case that was modeled as a two-dimensional rectangular enclosure. Secondary sources and error sensors were locate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 127 2  شماره 

صفحات  -

تاریخ انتشار 2010