Clinical-angiographic correlation of ophthalmodynamometry in patients with suspected carotid artery disease: a prospective study.

نویسندگان

  • G E Sanborn
  • N R Miller
  • M McGuire
  • A J Kumar
چکیده

A prospective, clinical study was performed on patients with suspected carotid artery disease to compare the accuracy of compression and suction ophthalmodynamometry with carotid artery stenosis as determined by arteriography. Results were analyzed with respect to current criteria for classification and determination of "significant" carotid artery disease. Although our results suggest that the best correlation for both procedures with arteriography is a ratio of the corrected intraocular pressure to the systolic brachial blood pressure, these results were not statistically improved over those obtained using uncorrected systolic or diastolic values. Both suction and compression ophthalmodynamometry are equally accurate with levels approaching 80 percent; however, neither test is sensitive enough to be used alone as a screening technique. Arteriography remains the best procedure for the determination of carotid artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical-Angiographic Correlation of Ophthaimodynamometry in Patients with Suspected Carotid Artery Disease: A Prospective Study

A prospective, clinical study was performed on patients with suspected carotid artery disease to compare the accuracy of compression and suction ophthaimodynamometry with carotid artery stenosis as determined by arteriography. Results were analyzed with respect to current criteria for classification and determination of "significant" carotid artery disease. Although our results suggest that the...

متن کامل

بررسی 291 مورد سونوگرافی داپلر کاروتید در بیماران کاندید CABG

Introduction: Doppler ultrasonography (DUS) is the most preferable method for screening of carotid artery disease in patients undergoing CABG. The purpose of this study was to investigate the frequency of carotid artery disease and determine the relation between known risk factors of atherosclerosis and rate of carotid artery narrowing in order to identify high-risk groups among patients schedu...

متن کامل

The detection of carotid artery obstruction: a correlation with arteriography.

The Detection of Carotid Artery Obstruction: A Correlation With A rteriography • Intravenous radioisotope arteriography, carotid compression ocular plethysmography, and supraorbital Doppler studies were more accurate than ophthalmodynamometry in the detection of the presence or absence of carotid artery obstruction in 35 patients. Abnormal results were present in patients with carotid obstructi...

متن کامل

Prevalence of carotid arterial diseases in patients undergoing CABG operations

 Introduction: Prevalence of stroke following coronary artery bypass graft surgery (CABG) is % 2.1-5.2 and associated with high mortality. The purpose of this study was to investigate the prevalence of carotid artery disease in patients undergoing CABG surgery.  Methods: This cross-sectional study was performed in the years 2010-2011 on 192 patients who underwent open heart surgery (CABG) in...

متن کامل

Ophthalmodynamometry in internal carotid artery occlusion.

Retinal artery pressure was measured by ophthalmodynamometry in 15 patients with occlusion of the internal carotid artery in its extracranial part. Nine of the patients had severe neurological deficit whereas the remaining six had slight or intermittent symptoms. Retinal artery pressure was reduced on the side of the internal carotid artery occlusion in all patients studied. Near-zero low diast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 1981