Decoupled Thermal Simulation

نویسندگان

  • SURENDRA GUNTUR
  • Surendra Guntur
  • Pierre Michaud
چکیده

Small transistors and high clock frequency have resulted in high power density, which makes temperature a strong constraint in today’s microprocessor design. For maximizing performance, the thermal design power must be set according to average, instead of worst case, conditions. Consequently, current processors feature temperature sensors and throttling mechanisms to keep the chip temperature at a safe level. To study future thermallyconstrained processors and systems, researchers and engineers use cycle-accurate performance simulators modeling power consumption and temperature. Cycle-accurate simulators are relatively slow and make it difficult to study long-term thermal behaviors that may require to simulate several minutes or even hours of processor execution. Sampling or phase analysis cannot be applied directly in this case because temperature depends on all past energy events. We propose a partial solution to this problem, which consists in decoupling cycle-accurate simulations and thermal ones. Temperature-unaware cycle-accurate simulation is used to generate an energy trace representing the complete execution of an application. Phase analysis can be used to decrease the trace generation time and make compact traces. Temperature and thermal-throttling are simulated in a separate thermal simulator that reads energy traces. The thermal simulator is faster than the cycle-accurate one and can be used to explore, with the same energy trace, parameters that are not modeled in cycle-accurate simulation. Key-words: Temperature-constrained processor, performance, energy, simulation, program phase reuse.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pareto Optimal Design Of Decoupled Sliding Mode Control Based On A New Multi-Objective Particle Swarm Optimization Algorithm

One of the most important applications of multi-objective optimization is adjusting parameters ofpractical engineering problems in order to produce a more desirable outcome. In this paper, the decoupled sliding mode control technique (DSMC) is employed to stabilize an inverted pendulum which is a classic example of inherently unstable systems. Furthermore, a new Multi-Objective Particle Swarm O...

متن کامل

Sliding mode thermal control system for space station furnace facility

-This paper addresses the decoupled control of the nonlinear, multiinput-multioutput, and highly coupled space station furnace facility (SSFF) thermal control system. Sliding mode control theory, a subset of variable-structure control theory, is employed to increase the performance, robustness, and reliability of the SSFF's currently designed control system. This paper presents the nonlinear th...

متن کامل

Sliding Mode Thermal Control System For Space Station Furnace Facility - Control Systems Technology, IEEE Transactions on

This paper addresses the decoupled control of the nonlinear, multiinput–multioutput, and highly coupled space station furnace facility (SSFF) thermal control system. Sliding mode control theory, a subset of variable-structure control theory, is employed to increase the performance, robustness, and reliability of the SSFF’s currently designed control system. This paper presents the nonlinear the...

متن کامل

Note on the thermal history of decoupled massive particles

This note provides an alternative approach to the momentum decay and thermal evolution of decoupled massive particles. Although the ingredients in our results have been addressed in Ref.[1], the strategies employed here are simpler, and the results obtained here are more general.

متن کامل

A New Non-linear Control of the Four-Leg Inverter with Decoupled Model and Fast Dynamic Response for PV Generation Systems

Distributed generation (DG) will play an important role in future power generation systems, especially in stand-alone applications. Three phase four-leg inverter is a well-known topology which can be used as an interface power converter for DGs. Thanks to the fourth leg to provide the neutral path, the four-leg inverter is able to supply balanced loads as well as unbalanced loads. In this paper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008