Monte Carlo Method for Radiological X-ray Examinations

نویسندگان

  • D. FULEA
  • I. G. POP
  • Iuliu Moldovan
  • D. Fulea
  • C. Cosma
  • I. G. Pop
چکیده

The organ doses and the effective dose of patients exposed at an X-ray beam, having photon energies between 10–150 keV, are analyzed by using a new method named IradMed. Three major radiological procedures, mammography, radiography and Computer Tomography are considered. The Rayleigh scattering, the Compton scattering and the photoelectric effect were taken into account for patient dose calculations. The Compton scattering is modeled by using “classic”, Kahn, Wielopolski and EGS procedures. The best results for angular distribution was obtained when the EGS-based algorithm was used. It can be noted that patient doses determined by using Kahn or “classic” procedures are in good agreement with data from literature when similar computing methods are used. From our data, for patient dose calculations, the EGS procedure is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

متن کامل

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Evaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran

Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009