k-space undersampling in PROPELLER imaging.

نویسندگان

  • Konstantinos Arfanakis
  • Ashish A Tamhane
  • James G Pipe
  • Mark A Anastasio
چکیده

PROPELLER MRI (periodically rotated overlapping parallel lines with enhanced reconstruction) provides images with significantly fewer B(0)-related artifacts than echo-planar imaging (EPI), as well as reduced sensitivity to motion compared to conventional multiple-shot fast spin-echo (FSE). However, the minimum imaging time in PROPELLER is markedly longer than in EPI and 50% longer than in conventional multiple-shot FSE. Often in MRI, imaging time is reduced by undersampling k-space. In the present study, the effects of undersampling on PROPELLER images were evaluated using simulated and in vivo data sets. Undersampling using PROPELLER patterns with reduced number of samples per line, number of lines per blade, or number of blades per acquisition, while maintaining the same k-space field of view (FOV(k)) and uniform sampling at the edges of FOV(k), reduced imaging time but led to severe image artifacts. In contrast, undersampling by means of removing whole blades from a PROPELLER sampling pattern that sufficiently samples k-space produced only minimal image artifacts, mainly manifested as blurring in directions parallel to the blades removed, even when reducing imaging time by as much as 50%. Finally, undersampling using asymmetric blades and taking advantage of Hermitian symmetries to fill-in the missing data significantly reduced imaging time without causing image artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact Reduction in undersampled BLADE/PROPELLER MRI by k-space extrapolation using parallel imaging

M. Blaimer, K. Barkauskas, S. Kannengiesser, F. Breuer, P. M. Jakob, J. L. Duerk, M. A. Griswold Department of Radiology, University Hospitals of Cleveland and Case Western Reserve University, Cleveland, OH, United States, Siemens Medical Solutions, Erlangen, Germany, Department of Experimental Physics 5, University of Wuerzburg, Wuerzburg, Germany Introduction: BLADE (a.k.a., PROPELLER) MRI me...

متن کامل

Random phase modulation of spatial aliasing in temporal domain for dynamic MRI

Introduction: Parallel imaging has been widely used in dynamic MRI for improved spatial or temporal resolution. In this study, we propose a new k-t space sampling trajectory for dynamic parallel imaging techniques. This method applies a random phase modulation to the spatial aliasing of images in temporal domain. As a result, the spatial aliasing induced by k-space undersampling at every time f...

متن کامل

Functional magnetic resonance imaging using PROPELLER-EPI.

Periodically rotated overlapping parallel lines with enhanced reconstruction-echo-planar imaging (PROPELLER-EPI) is a multishot technique that samples k-space by acquisition of narrow blades, which are subsequently rotated until the entire k-space is filled. It has the unique advantage that the center of k-space, and thus the area containing the majority of functional MRI signal changes, is sam...

متن کامل

Interpolated Compressed Sensing for 2D Multiple Slice Fast MR Imaging

Sparse MRI has been introduced to reduce the acquisition time and raw data size by undersampling the k-space data. However, the image quality, particularly the contrast to noise ratio (CNR), decreases with the undersampling rate. In this work, we proposed an interpolated Compressed Sensing (iCS) method to further enhance the imaging speed or reduce data size without significant sacrifice of ima...

متن کامل

Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k

Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 53 3  شماره 

صفحات  -

تاریخ انتشار 2005