Operational Implementation of LED Fluorescence Microscopy in Screening Tuberculosis Suspects in an Urban HIV Clinic in Uganda
نویسندگان
چکیده
BACKGROUND Light emitting diode (LED) fluorescence microscopy (FM) is an affordable, technology targeted for use in resource-limited settings and recommended for widespread roll-out by the World Health Organization (WHO). We sought to compare the operational performance of three LED FM methods compared to light microscopy in a cohort of HIV-positive tuberculosis (TB) suspects at an urban clinic in a high TB burden country. METHODS Two spot specimens collected from TB suspects were included in the study. Smears were stained using auramine O method and read after blinding by three LED-based FM methods by trained laboratory technicians in the Infectious Diseases Institutelaboratory. Leftover portions of the refrigerated sputum specimens were transported to the FIND Tuberculosis Research Laboratory for Ziehl Neelsen (ZN) smear preparation and reading by experienced technologist as well as liquid and solid culture. RESULTS 174 of 627 (27.8%) specimens collected yielded one or more positive mycobacterial cultures. 94.3% (164/174) were M. tuberculosis complex. LED FM was between 7.3-11.0% more sensitive compared to ZN microscopy. Of the 592 specimens examined by all microscopy methods, there was no significant difference in sensitivity between the three LED FM methods. The specificity of the LED FM methods was between 6.1% and 7.7% lower than ZN microscopy (P<0.001), although exclusion of the single poor reader resulted in over 98% specificity for all FM methods. CONCLUSIONS Laboratory technicians in routine settings can be trained to use FM which is more sensitive than ZN microscopy. Despite rigorous proficiency testing, there were operator-dependent accuracy issues which highlight the critical need for intensive quality assurance procedures during LED FM implementation. The low sensitivity of FM for HIV-positive individuals particularly those with low CD4 T cell counts, will limit the number of additional patients found by LED FM in countries with high rates of HIV co-infection.
منابع مشابه
Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda
BACKGROUND Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings. METHODS We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primost...
متن کاملImplementation and effect of intensified case finding on diagnosis of tuberculosis in a large urban HIV clinic in Uganda: a retrospective cohort study.
BACKGROUND Increased detection of tuberculosis (TB) using intensified or active case finding (ICF) is one of the cornerstones of the Stop TB Strategy, and contrasts with passive case finding (PCF) which relies on self-reported symptoms. There is no clear guidance on implementation strategies. We implemented ICF in addition to ongoing PCF in our large urban HIV clinic in July 2010 using a twice-...
متن کاملImplementation of LED Fluorescence Microscopy for Diagnosis of Pulmonary and HIV-Associated Tuberculosis in a Hospital Setting in Indonesia
BACKGROUND Fluorescence microscopy (FM) has not been implemented widely in TB endemic settings and little evaluation has been done in HIV-infected patients. We evaluated diagnostic performance, time and costs of FM with light-emitting diodes technology (LED-FM), compared with conventional (Zieh-Neelsen) microscopy in a hospital in Indonesia which acts as referral centre for HIV-infected patient...
متن کاملClinical Predictors and Accuracy of Empiric Tuberculosis Treatment among Sputum Smear-Negative HIV-Infected Adult TB Suspects in Uganda
INTRODUCTION The existing diagnostic algorithms for sputum smear-negative tuberculosis (TB) are complicated, time-consuming, and often difficult to implement. The decision to initiate TB treatment in resource-limited countries is often largely based on clinical predictors. We sought to determine the clinical predictors and accuracy of empiric TB treatment initiation in HIV-infected sputum smear...
متن کامل[Performance of LED fluorescence microscopy for the detection of acid-fast bacilli from respiratory samples in peripheral laboratories in Argentina].
INTRODUCTION Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance. OBJECTIVE To evaluate the performance of LED-FM for tuberculosis diagnosis in patients...
متن کامل