Non-Conventional Power Generation Using Solar And Wind With The Aid Of Hydro Power Generation

نویسنده

  • Sandeep Puppala
چکیده

The latest trend in generating power for industrial and domestic purposes is the hybrid power generation using non-conventional energy sources. The non-conventional energy sources are the renewable sources that can be utilized again after every use and also whose supply is abundant in nature. This paper presents a new system configuration of the front-end rectifier stage for a hybrid wind/photovoltaic energy system. The configuration allows the two sources to supply load simultaneously depending on the availability of energy sources. This paper also describes about the design aspects of the renewable energy sources like Solar (PV) and Wind. PV/Wind module designs, parameters are mentioned in this particular paper. Operational analysis of the proposed system will be discussed in this paper. Simulation results are given to highlight the merits of the proposed circuit. Keywords— PV cells, Irradiation, Insolation, Wind turbine, Hydro turbine, Synchronous Machine, Inverter. I. BASIC PV CELL MODEL Fig.1. Equivalent Solar cell developed in Simulink/Simpowersystem Operation of PV: A solar cell is the most fundamental component of a photovoltaic (PV) system, which converts the solar energy into electrical energy. A solar cell essentially consists of a pn junction formed by semiconductor material. When sunlight falls on a solar cell an electron-hole pair is generated by the energy from the light (photons). The electric field created at the junction causes the electron-hole pair to separate with the electrons drifting towards the n-region and the holes towards the p-region. Thus there is a bombardment of electrons and holes resulting in the generation of energy. Hence electrical voltage is generated at the output. The photocurrent (Iph) will then flow through the load connected to the output terminals of the cell [5]. The ideal equivalent circuit of a solar cell consists of a current source in parallel with a diode. The output terminals of the circuit are connected to the load. Ideally the voltagecurrent equation of the solar cell is given by [3]: I= IPhIo (e ( V+iRs/nsvt) -1) – (v+iRs)/Rsh (1) Where: Iph = Photo current (A) Io = Diode Reverse saturation current(A) Vt = Junction terminal voltage v = terminal voltage Rs = Panel series Resistance Rsh = Panel shunt Resistance ns =Number of cells in panel connected in series The power output of a solar cell is given by: PPV=Vpv*IPV (2) Where: IPV = Output current of solar cell (A). VPV = Solar cell operating voltage (V). PPV = Output power of solar cell (W). Sandeep Puppala, M Ebraheem / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 4, July-August 2012, pp.271-274 272 | P a g e II. WIND ENERGY CONVERTION SYSTEM AND ITS OPERATION Fig.2. Wind conversion system The wind energy system here consists of a Permanent Magnet Synchronous Generator (PMSG) that converts the rotational movement of the rotor of the wind turbine to the electrical output. The output of the wind turbine is controlled using a control block which consists of the Pitch angle, Wind speed and Generator speed [4]. This output which is an AC is converted into DC using a rectifier to combine it with the existing PV module output which is also DC [1], [2]. III. HYDRO ELECTRIC SYSTEM AND ITS OPERATION This model comprises of a 3-phase synchronous machine associated with the Hydraulic turbine and Governor and Excitation systems. The d-axis and the q-axis time constants are short circuited and open circuited respectively. The stator winding are connected in wye to an internal neutral point. The Hydraulic Turbine and Governor block implements a nonlinear hydraulic turbine model, a PID governor system, and a servomotor. Fig. 3. Hydraulic Turbine Governor model. Wref = Reference speed, in pu Pref = Reference mechanical power in pu. This input can be left unconnected if you want to use the gate position as input to the feedback loop instead of the power deviation. We = Machine actual speed, in pu. Pe0 = Machine actual electrical power in pu. This input can be left unconnected if you want to use the gate position as input to the feedback loop instead of the power deviation. Dw = Speed deviation, in pu. Pm = Mechanical power Pm for the Synchronous Machine block, in pu. Gate = Gate opening, in pu. Fig 4. Excitation system Model Vref = The desired value, in pu, of the stator terminal voltage. Vd = vd component, in pu, of the terminal voltage. Vq = vq component, in pu, of the terminal voltage. Vstab = Connect this input to a power system stabilizer to provide additional stabilization of power system oscillations. Vf = The field voltage, in pu, for the Synchronous Machine block. IV. INVERTER The combined outputs of all the three sources i.e. Wind and PV and Hydro which is a DC are fed as input to an inverter or a pulse triggered thyristor [1]. This inverter then converts the DC into AC. The rectified AC is then given to loads. V. PROPOSED MODEL FOR BOTH PV, WIND and HYDRO The model shows the proposed model for the combined operation of both PV and Wind modules along with the Hydro generating source. The Wind system, the PV system and the Hydro system are combined together and is fed to a DC/AC inverter. The then output which is AC is given to the load [7] [8]. Sandeep Puppala, M Ebraheem / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 4, July-August 2012, pp.271-274 273 | P a g e Fig.5. Proposed model for PV, Wind and Hydro sytems VI. SIMULINK MODEL OF THE PROPOSED SYSTEM Fig.6. Simulink model for the proposed Hybrid system VII. SIMULATION RESULTS Fig.7. DC Output of PV Module. Fig.8. DC Output of Wind Module. Fig.9. Single Phase Voltages of PV, Wind and Hydro Models Sandeep Puppala, M Ebraheem / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 4, July-August 2012, pp.271-274 274 | P a g e Fig.10. 3-Phase Voltages of PV, Wind and Hydro Models Fig.11. 3-Phase Output Power at Load VIII. ANALYSISThe above figures are the obtained simulationoutputs for PV, Wind and Hydro energy systems. The figuresstarting from fig to fig, there is a gap from time 0.4 to 0.6 andfrom which is called as the “Dead Time” or “No OperationZone”. This is created to know that PV energy sourceoperates from 0 to 0.4 and Wind energy source operates from0.6 to 0.8 and Hydro energy source from 1 to 1.4. Thepurpose of introducing Hydro generation is to compensatethe loss of power at the load during power mismatch. Thispaper is limited to small amount of power generation forsmall application purposes. The generation can be increasedfurther by increasing the number of PV cells in the case ofPV module and the turbine performance of the wind modulecan be improved by replacing the existing model. IX. CONCLUSIONIt has been observed that the combination of bothPV and Wind modules can deliver sufficient power to theload as long as source for both exists. If there is an increasein load or failure of either of PV and Wind sources, Hydrocan serve as the backup for providing continuous supply. Thedead time can be compensated with the aid of Hydro Powergenerating source.X. REFERENCES[1] joanne hui*, alireza bakhshai and praveen k. jain, “ahybrid wind-solar energy system: a new rectifier stagetopology”, ieee transactions on energy conversion,2010.[2] adel m. sharaf mohamed a. h. el-sayed centre ofenergy studies university of trinidad and tobago, pointlisas campus, esperanza road, brechin castle, couva, “anovel hybrid integrated wind-pv micro co-generationenergy scheme for village electricity.[3] michael jensen, russell louie, mehdi etezadi-amoli, andm. sami fadali, “modelling and simulation of 75kw pvsolar array”.[4] s.k. kim, j.h jeon, c.h. cho, j.b. ahn, and s.h. kwon,“dynamic modeling and control of a grid-connectedhybrid generation system with versatile powertransfer,” ieee transactions on industrial electronics,vol. 55, pp. 1677-1688, april 2008.[5] d. das, r. esmaili, l. xu, d. nichols, “an optimal designof a grid connected hybrid wind/photovoltaic/fuel cellsystem for distributed energy production,” in proc.ieee industrial electronics conference, pp. 2499-2504,nov. 2005.[6] n. a. ahmed, m. miyatake, and a. k. al-othman, “powerfluctuations suppression of stand-alone hybridgeneration combining solar photovoltaic/wind turbineand fuel cell systems,” in proc. of energy conversionand management, vol. 49, pp. 2711-2719, october2008.[7] nabil a. ahmed and masafumi miyatake sophiauniversity,tokyo,japanEmail:[email protected], “A Stand-AloneHybrid Generation System Combining SolarPhotovoltaic and Wind Turbine with SimpleMaximum Power Point Tracking Control”.[8] Dorin Brik, Cristian Dragois, Adrian Gligor, “PetruMaior” University of Tg Mures, ElectricalEngineering Department, Romania.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generation Scheduling in Large-Scale Power Systems with Wind Farms Using MICA

The growth in demand for electric power and the rapid increase in fuel costs, in whole of theworld need to discover new energy resources for electricity production. Among of the nonconventionalresources, wind and solar energy, is known as the most promising deviceselectricity production in the future. In this thesis, we study follows to long-term generationscheduling of power systems in the pre...

متن کامل

Stochastic Short-Term Hydro-Thermal Scheduling Based on Mixed Integer Programming with Volatile Wind Power Generation

This study addresses a stochastic structure for generation companies (GenCoʼs) that participate in hydro-thermal self-scheduling with a wind power plant on short-term scheduling for simultaneous reserve energy and energy market. In stochastic scheduling of HTSS with a wind power plant, in addition to various types of uncertainties such as energy price, spinning /non-spinning reserve prices, unc...

متن کامل

Economic assessment of renewable power generation based on wind speed and solar radiation in urban regions

Economic evaluation of 12 MW grid-connected wind farms and PV power plants in two regions in Northern Cyprus for electricity generation was investigated. The wind speed, sunshine duration, and solar global radiation characteristics were analyzed using monthly data collected over 17 years (2000-2016) for Girne and nine years (2008-2016) for Lefkoşa, which were measured at various heights. The re...

متن کامل

Optimal Coordinated Voltage Control in Distribution Networks in presence of Solar and Wind Power Plants Considering Uncertainties

Abstract: In the last decade, the amount of distributed generation connected to the distribution network is increasing. The presence of distributed generation resources in distribution systems has a great influence on its behavior and it is necessary to consider the impact of these resources on the distribution network design. In this study, Optimal Coordinated Voltage Control (OCVC) using wind...

متن کامل

Optimal Short-Term Coordination of Desalination, Hydro and Thermal Units

The fossil fuels consumption is rapidly growing due to increased water and electricity demands. An interconnected water-energy nexus is generally composed of thermal power plants, combined potable water and power (CWP) generation units, and desalination only processes. Hence, participation of hydro power plants in electricity generation facilities not only reduces the total fuel consumption of ...

متن کامل

Risk Analysis and Economic Load Dispatch Evaluation of Network with High Wind Power Penetration

This study based on investigation for integration wind power into conventional power system with its impact on fossil fuel generators and their generation management. Wind power as environmental friendly energy source can reduce the operational cost of the system due to considering no cost for energizing the generator in comparing with fossil fuel generators. However due to unpredictable nature...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012