24-Hour Urine Samples Are More Reproducible Than Spot Urine Samples for Evaluation of Iodine Status in School-Age Children.
نویسندگان
چکیده
BACKGROUND Variation in different urinary measurements for evaluation of iodine status is of concern to clinicians and researchers. OBJECTIVE This study evaluated variations between urine iodine concentration (UIC), spot and 24-h urine sample creatinine concentrations, and 24-h urine iodine excretion (24-h UIE) in repeated samples from school-age children. METHODS Urine samples (24 h and morning spot) were collected on 2 occasions from 981 children in Ningjin and Lingxian counties, China. Samples from Ningjin were collected in October and November 2013, and samples from Lingxian were collected in April and May 2014. Morning spot urine iodine concentration (MUIC), morning spot urine creatinine, 24-h UIC, and 24-h urine creatinine were measured in all samples. The 24-h UIE was calculated by multiplying the 24-h UIC by the 24-h urine volume. RESULTS In Ningjin County, the 24-h UIC and 24-h UIE did not differ between repeated collections [192 and 172 μg/L, respectively, for 24-h UIC (P = 0.08); 123 and 120 μg/L, respectively, for 24-h UIE (P = 0.56)], whereas the MUIC was lower in November 2013 than in October 2013 (170 and 190 μg/L, respectively; P = 0.034). In Lingxian County, no significant differences were observed in 24-h UIC between the repeated collections (230 and 218 μg/L, respectively; P = 0.79), whereas the 24-h UIE and MUIC were higher in the samples collected in May 2014 than in April 2014 [161 and 155 μg/L, respectively, for 24-h UIE (P = 0.002); 244 and 203 μg/L, respectively, for MUIC (P < 0.001)]. When data from both counties were combined, no difference was observed between repeated 24-h UIC (214 compared with 196 μg/L; P = 0.17) and 24-h UIE (143 compared with 143 μg/d; P = 0.06), but MUICs were lower in the first collection than in the second collection (199 and 207 μg/L, respectively; P = 0.002). The κ values were >0.4 for 24-h UIC and mean UIE, whereas relatively low κ values were observed for MUIC and mean UIE. CONCLUSION The 24-h UIC was more accurate and reproducible than the MUIC in evaluating iodine status in a large-scale population study of school-age children.
منابع مشابه
Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.
BACKGROUND Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare wit...
متن کاملIodine Intakes of Victorian Schoolchildren Measured Using 24-h Urinary Iodine Excretion
Mandatory fortification of bread with iodized salt was introduced in Australia in 2009, and studies using spot urine collections conducted post fortification indicate that Australian schoolchildren are now replete. However an accurate estimate of daily iodine intake utilizing 24-h urinary iodine excretion (UIE μg/day) has not been reported and compared to the estimated average requirement (EAR)...
متن کاملEstimation of iodine intake from various urinary iodine measurements in population studies.
BACKGROUND Iodine intake is often measured by a surrogate measure, namely urine iodine excretion as almost all ingested iodine is excreted in the urine. However, the methods for urine collection and the reporting of the results vary. These methods, and their advantages and disadvantages, are considered in this article. SUMMARY There are two main ways in which urine can be collected for iodine...
متن کاملReliability of studies of iodine intake and recommendations for number of samples in groups and in individuals.
The iodine intake level in a population is determined in cross-sectional studies. Urinary iodine varies considerably and the reliability of studies of iodine nutrition and the number of samples needed is unsettled. We performed a longitudinal study of sixteen healthy men living in an area of mild to moderate iodine deficiency. Iodine and creatinine concentrations were measured in spot urine sam...
متن کاملEvaluation of 8-hour and 12-hour urine collection for detection of proteinuria in hypertensive women, Shariati hospital, 2004 - 2005
Introduction: Hypertensive disorders are common during pregnancy. Combination of hypertension and proteinuria markedly increase prenatal morbidity and mortality. The gold standard method for proteinuria assessment is 24-hour urine collection. This survey is designed to determine the correlation between protein content of 8-hour and 24-hour urine collections. Methods: This cross-sectional study...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of nutrition
دوره 146 1 شماره
صفحات -
تاریخ انتشار 2016