SU-E-T-110: Small Electron Field Surface Dosimetry Using Solid State Detectors.

نویسندگان

  • S Tanny
  • B Gautam
  • D Pearson
  • E Parsai
چکیده

PURPOSE Solid state detectors from two independent systems have shown similar over-responses to small electron fields used for treatment of surface lesions. We propose to evaluate the accuracy of solid state detector systems for highly blocked electron fields as a method for clinical dosimetry and determine the cause for any deviations from expected dose-delivery calculations. METHODS A QED Diode detector system and a Best-Medical MOSFET dosimeter system were used to measure relative output factors (ROF's) for a range of blocked electron fields with 3 different electron energies. Measurements were taken on the surface of a Solid-Water phantom as well as under varying thicknesses of bolus (surface to dmax) to determine the extent of this effect with increasing depth. Measurements were compared with expected results obtained during machine commissioning with an A-14 micro-ionization chamber. RESULTS Field sizes larger than 4×4 cm2 showed little significant deviation from expected output factor values. However, fields smaller than this threshold showed as much as a 30% over-response of the solid state detectors compared to ion chamber measurements on the surface. This deviation was consistent over multiple measurements using both systems. The degree of over-response is both energy and effective field size dependent. As the effective depth of measurement increases, the relative differences in responses decrease and eventually converge. CONCLUSIONS Surface dosimetry using solid state detectors is a straightforward method of verifying dosimetric calculations. Care must be taken when using these systems for surface dosimetry with highly blocked fields as their non-tissue equivalence makes these detectors overly sensitive to low-energy scattered electrons and bremsstrahlung photons produced from the block edge. Measurements taken near dmax will not show a significant deviation from the actual dose and do not need to account for this effect.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characteristics of active solid state detectors in a 60 MeV proton radiotherapy beam

The solid state active detectors, widely used for conventional radiotherapy, such as diamond detectors (DD) and diodes may be attractive tools also in dosimetry of therapeutic proton beams. Diodes are broadly applied in oncology clinics and routinely used for in-vivo dosimetry [1, 8]. These real-time detectors are rugged, relatively inexpensive and provide on-line readings, what allows for quic...

متن کامل

Small field electron beam dosimetry using MOSFET detector

The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becomin...

متن کامل

Estimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods

Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

متن کامل

13 USING NATURAL LUMINESCENT MATERIALS AND HIGHLY SENSITIVE SINTERED DOSIMETERS MCP-N (LiF:Mg,Cu,P) IN RADIATION DOSIMETRY

The main trend in radiation dosimetry nowadays is the use of solid state detectors. Luminescent dosimetric techniques are part of this field. This paper aims to present the application of thermoluminescence as a tool in measuring natural nuclear radiation, namely the application of highly sensitive sintered dosimeters MCP-N (LiF:Mg,Cu,P) in environmental monitoring and the possibility of using ...

متن کامل

Semiconductor Detectors in Radiation Medicine:

Semiconductor radiation detectors play an important role in radiation instrumentation. They have many advantages due to their small size, outstanding energy resolution in nuclear spectroscopy, easy pixilation for high spatial resolution and ability of integration with readout electronics. Advancement in microelectronic industry made silicon one of the most popular material for radiation detecto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part11  شماره 

صفحات  -

تاریخ انتشار 2012