Hemolysis during leukocyte-reduction filtration of stored red blood cells.
نویسندگان
چکیده
Hemolysis has been reported in red blood cells (RBCs) that have undergone leukocyte-reduction filtration. This study investigated whether the age of RBCs or the filter type affected hemolysis. One hundred eighty units of RBCs (adenine-saline added) were leukocyte-reduced by filtration. At each of the 6 weeks of shelf life, 10 units were filtered with the "BPF4" filter, 10 units with the "Purecell RCQ" filter, and 10 units with the "Sepacell" filter. Filtration was performed with strict adherence to the manufacturers' directions. Pre- and post-filtration samples were assayed for plasma hemoglobin by measuring the plasma absorbances at 578 nm and 562 nm. The increase of plasma hemoglobin concentration following filtration was significantly greater (p < 0.05) in older units, compared to fresher units, when the Sepacell and BPF4 filters were used. For example, the increase of plasma hemoglobin at week 6 (83.47 mg/dl:Sepacell, 128.93 mg/dl BPF4) was significantly greater than at week 1 (7.07 mg/dl Sepacell, 4.77 mg/dl BPF4) (Sepacell: p=0.008; BPF4: p=0.006). For units stored 1, 2, 4, 5, or 6 weeks, the increase of plasma hemoglobin concentration post-filtration was significantly greater with the BPF4 filter, compared to the Purecell RCQ filter (p <0.045); for units stored 5 weeks, the increase in plasma hemoglobin concentration post-filtration was significantly greater with the BPF4 filter compared to the Sepacell filter (p = 0.009). Mean filtration times were significantly longer in older units compared to fresh units. This study shows that increased storage duration of RBCs (adenine-saline added) is attended by greater hemolysis during leukocyte-reduction filtration and by prolongation of the filtration time. In addition, the amount of hemolysis may be influenced by the type of filter.
منابع مشابه
A Root Cause Analysis of Haemolysis Encountered in Leuco-filtration of Stored Packed Red Cells Units
Background and Aims: Leukoreduction of blood components has reduced the incidence of transfusion-associated adverse events. Leucofiltration is the most effective method of leukoreduction. We encountered haemolysis in a series of leucofiltered units. This stressed our precious inventory, added to financial loss, increased our turn-around time to issue leucofiltered blood units, and placed doubts...
متن کاملThe Alterations of Plasma Iipid Peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase Enzyme Activities During Storage of Blood
Abstract Background and objective: Exposure of red blood cells to oxygen radicals can induce Lipid proxidation, hemoglobin damage and hemolysis of erythrocyte .The present study was designed to determine the alteration of plasma lipid peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase enzyme activities in stored blood and to find out the quantitative alterations and th...
متن کاملCollection and storage of leukocyte depleted whole blood in autologous blood predeposit in elective surgery programs.
INTRODUCTION The aim of this investigation was to provide evidence that leukocyte depleted whole blood meets the requirements for transfusion of the European Council and thus may be an alternative to leukocyte and plasma depleted packed red blood cells in autologous blood predeposit for patients undergoing elective surgery programs. MATERIAL AND METHODS Standard units of 450mL blood were coll...
متن کاملتاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکتها در فراوردههای پلاکتی
Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of clinical and laboratory science
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2000