OBJECTIVE The Visual Input/Output Locator Algorithm (VIOLA) is a software-assisted method for prescribing amplification targets and selecting a hearing aid to match the targets. Although the procedure calls for selection and fitting of hearing aids in terms of their pure-tone input/output functions in a coupler, it is assumed that a hearing aid that matches the coupler prescription targets will produce specific amplified speech levels in the patient's ear canal. This investigation evaluated the validity of that assumption. DESIGN Six hearing aids were evaluated. They were representative of linear and compression processing as well as single- and 2-channel designs. The "subject" was a KEMAR manikin with realistic assumed hearing loss and loudness perception characteristics. Each hearing aid was configured to match the subject's VIOLA prescription as closely as possible. Predicted ear canal speech levels were determined using the prescription rules and modified by the differences between coupler prescription targets and coupler performance of the actual hearing aids. With the subject wearing each hearing aid coupled to an unvented earmold, continuous speech was presented in the sound field and measured, after amplification, in the ear canal. The match between observed and predicted levels of amplified speech indicated the validity of the VIOLA assumptions under examination. RESULTS The match between predicted and observed levels was good for soft speech input levels. As speech input levels increased, the differences between observed and predicted levels also increased, with the largest differences seen for loud speech inputs. When differences were seen between observed and predicted levels, they were always in the direction of lower than predicted ear canal levels. The differences between observed and predicted levels were attributed to the effects of limiting, effects of compression ratio in wide range compression, the individual subject's field-to-microphone transfer function, and the subject's individual real-ear-to-coupler level difference. CONCLUSIONS Ear canal speech levels were reasonably close to predicted values, and the deviations from predicted levels were plausibly accounted for by consideration of hearing aid performance. Thus, the approach used by the VIOLA procedure holds considerable promise for extending clinical control over the complex and interactive parameters of nonlinear hearing aids. The results of this study indicate that selection and fitting of hearing aids using the current VIOLA procedure usually will result in the generation of lower than predicted ear canal speech levels, especially for loud speech inputs. However, the accuracy of the procedure could be improved substantially by modification of the software to account for the effects of limiting and those of the compression ratio in systems with compression thresholds lower than the level of unamplified loud speech.
منابع مشابه
The Effect of Comprehensible Input and Comprehensible Output on the Accuracy and Complexity of Iranian EFL Learners’ Oral Speech
This study aimed at investigating the relative impact of comprehensible input and comprehensible output on the development of grammatical accuracy and syntactic complexity of Iranian EFL learners’ oral production. Participants were 60 female EFL learners selected from a whole population pool of 80 based on the standard test of IELTS. To investigate the research questions, the participants were ...
متن کاملEvaluation of an in-situ output probe-microphone method for hearing aid fitting verification.
Several hearing aid prescription procedures specify frequency gain functions in terms of the desired levels of amplified speech. The most direct method for verifying hearing aid fittings based on these procedures requires a measurement of amplified speech in the ear canal. This paper describes the evaluation of a probe microphone measurement procedure designed to measure amplified speech to ver...
متن کاملMulti-Output Adaptive Neuro-Fuzzy Inference System for Prediction of Dissolved Metal Levels in Acid Rock Drainage: a Case Study
Pyrite oxidation, Acid Rock Drainage (ARD) generation, and associated release and transport of toxic metals are a major environmental concern for the mining industry. Estimation of the metal loading in ARD is a major task in developing an appropriate remediation strategy. In this study, an expert system, the Multi-Output Adaptive Neuro-Fuzzy Inference System (MANFIS), was used for estimation of...
متن کاملConformity of the real-ear aided response with the target response from the DSL v5 formula
Objectives: Real ear measurement plays a critical role in children’s hearing aid fitting. This study aimed to evaluate the conformity of measured and predicted real-ear aided response (REAR) of prescribed formula desired sensation level (DSL) v5 Pediatric in children aged 4 to 7 years. Since there is limited information about the effect of the degree of hearing loss (DOHL), ethnicity, gender, a...
متن کاملThree-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method
In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ear and hearing
دوره 19 2 شماره
صفحات -
تاریخ انتشار 1998