A Family of Simplified Geometric Distortion Models for Camera Calibration

نویسندگان

  • Lili Ma
  • Yangquan Chen
  • Kevin L. Moore
چکیده

The commonly used radial distortion model for camera calibration is in fact an assumption or a restriction. In practice, camera distortion could happen in a general geometrical manner that is not limited to the radial sense. This paper proposes a simplified geometrical distortion modeling method by using two different radial distortion functions in the two image axes. A family of simplified geometric distortion models is proposed, which are either simple polynomials or the rational functions of polynomials. Analytical geometric undistortion is possible using two of the distortion functions discussed in this paper and their performance can be improved by applying a piecewise fitting idea. Our experimental results show that the geometrical distortion models always perform better than their radial distortion counterparts. Furthermore, the proposed geometric modeling method is more appropriate for cameras whose distortion is not perfectly radially symmetric around the center of distortion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blind Detection and Compensation of Camera Lens Geometric Distortions

This paper presents a blind detection and compensation technique for camera lens geometric distortions. The lens distortion introduces higher-order correlations in the frequency domain and in turn it can be detected using higher-order spectral analysis tools without assuming any specific calibration target. The existing blind lens distortion removal method only considered a single-coefficient r...

متن کامل

Calibration Strategy for the Medusa Camera System

The MEDUSA camera system is a high resolution earth observation instrument designed to operate from a long endurance UAV flying at stratospheric altitudes. Due to the technical constraints imposed on the instrument regarding mass, power and dimensions, the MEDUSA instrument shall experience large temperature variations induced by its varying environment in which it is operated. The induced phys...

متن کامل

Automatic Camera Calibration in Close-range Photogrammetry

Automatic camera calibration via self-calibration with the aid of coded targets is now very much the norm in closerange photogrammetry. This is irrespective of whether the cameras to be calibrated are high-end metric, or the digital SLRs and consumer-grade models that are increasingly being employed for image-based 3D measurement. Automation has greatly simplified the calibration task, but ther...

متن کامل

Geometric Modelling and Calibration of Fisheye Lens Camera Systems

The paper describes a geometric projection model for fisheye lenses and presents results of the calibration of fisheye lens camera systems based on it. For fisheye images the real projection model does not comply with the central perspective. In addition, the lenses are subject to considerable distortions. The fisheye lens projection follows an approximately linear relation between the incidenc...

متن کامل

Calibration of geometric distortion in the ACS detectors

The off-axis location of the Advanced Camera for Surveys causes strong geometric distortion in all detectors – the Wide Field Camera (WFC), High Resolution Camera (HRC), and Solar Blind Camera (SBC). Dithered observations of rich star cluster fields are used to calibrate the dirtortion. We describe the observations obtained, the algorithms used to perform the calibrations and the accuracy achie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CoRR

دوره cs.CV/0308003  شماره 

صفحات  -

تاریخ انتشار 2003