Experimental research on intraocular aqueous flow by PIV method
نویسندگان
چکیده
BACKGROUND Aqueous humor flows regularly from posterior chamber to anterior chamber, and this flow much involves intraocular pressure, the eye tissue nutrition and metabolism. PURPOSE To visualize and measure the intraocular flow regular pattern of aqueous humor. METHOD Intraocular flow in the vitro eyeball is driven to simulate the physiological aqueous humor flow, and the flow field is measured by Particle Image Velocimetry(PIV). Fluorescent particle solution of a certain concentration was infused into the root of Posterior Chamber(PC) of vitro rabbit eye to simulate the generation of aqueous and was drained out at a certain hydrostatic pressure from the angle of Anterior Chamber(AC) to represent the drainage of aqueous. PIV method was used to record and calculate the flow on the midsagittal plane of the eyeball. RESULTS Velocity vector distribution in AC has been obtained, and the distribution shows symmetry feature to some extent. Fluorescent particle solution first fills the PC as it is continuously infused, then surges into AC through the pupil, flows upwards toward the central cornea, reflecting and scattering, and eventually converges along the inner cornea surface towards the outflow points at the periphery of the eyeball. Velocity values around the pupillary margin are within the range of 0.008-0.012 m/s, which are close to theoretical values of 0.0133 m/s, under the driving rate of 100 μl/min. CONCLUSIONS Flow field of aqueous humor can be measured by PIV method, which makes it possible to study the aqueous humor dynamics by experimental method. Our study provides a basis for experimental research on aqueous humor flow; further, it possibly helps to diagnose and treat eye diseases as shear force damage of ocular tissues and destructions on corneal endothelial cells from the point of intraocular flow field.
منابع مشابه
Development of a Low Cost and Safe PIV for Mean Flow Velocity and Reynolds Stress Measurements
In this study, a white light particle image velocimetry (WL PIV) system which employs a light sheet generated with a flash was used. The system was developed in order to provide a cost-efficient and safe alternative to laser systems while keeping the accuracy limits required for hydraulic model tests. To investigate the accuracy of WL PIV method under different flow conditions, experiments were...
متن کاملA manometric study of the rate of fall of the intraocular pressure in the living and dead eyes of human subjects.
The relationship between the rate of flow of the aqueous humor and the intraocular pressure in living and dead human eyes has been studied by two manometric techniques. The first comprised, a record of the pressure decay curve and a separate determination of the pressurevolume relationship for the same eye. The pressure-flow relationship was then calculated, from the rate of pressure change and...
متن کاملInvestigation of Unsteady Flow Fields for Flow Control Research by Means of Particle Image Velocimetry
Unsteady three-dimensional flow phenomena must be investigated and well understood to be able to design devices to control such complex flow phenomena in order to achieve the desired behavior of the flow and to assess their performance, even in harsh industrial environments. Experimental investigations for flow control research require measurement techniques capable to resolve the flow field wi...
متن کاملAcidosis, alkalosis, and aqueous humor dynamics in rabbits.
Systemic acidosis induced by intravenous administration of hydrochloric acid lowered intraocular pressure in unanesthetized rabbits. Aqueous humor flow was reduced by approximately 50%, as measured by the iodide method and as calculated from tonographic data. Outflow facility, episcleral venous pressure, plasma osmolality, blood pressure, pulse, and body temperature were not altered by systemic...
متن کاملPhosphate and Protein Concentrations of Intraocular Fluids. I. Effect of Carbonic Anhydrase Inhibition in Young and Old Rabbits.
The effects of a carbonic anhydrase inhibitor, dichlorphenamide, on the phosphate and protein concentrations of intraocular fluids have been studied. The administration of dichlorphenamide caused a marked increase in phosphate concentration of posterior and anterior aqueous humors. The changes in steady-state concentrations were compatible with a decrease in the flow coefficient of approximatel...
متن کامل