SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

نویسندگان

  • Wenmiao Lu
  • Kim Butts Pauly
  • Garry E Gold
  • John M Pauly
  • Brian A Hargreaves
چکیده

Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal-induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called "Slice Encoding for Metal Artifact Correction" (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each excited slice against metal-induced field inhomogeneities. The robust slice encoding is achieved by extending a view-angle-tilting (VAT) spin-echo sequence with additional z-phase encoding. Although the VAT compensation gradient suppresses most in-plane distortions, the z-phase encoding fully resolves distorted excitation profiles that cause through-plane distortions. By positioning all spins in a region-of-interest to their actual spatial locations, the through-plane distortions can be corrected by summing up the resolved spins in each voxel. The SEMAC technique does not require additional hardware and can be deployed to the large installed base of whole-body MRI systems. The efficacy of the SEMAC technique in eliminating metal-induced distortions with feasible scan times is validated in phantom and in vivo spine and knee studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR imaging after spinal fusion using Slice Encoding for Metal Artifact Correction (SEMAC)

INTRODUCTION: Failed Back Surgery Syndrome (FBSS) is a relatively common complication of lumbar spine surgery, occurring in between 5-10% of cases, and resulting in severe, chronic, and debilitating pain. MRI is often of limited value in these patients due to the significant metal artifact occurring around orthopedic hardware, particularly at higher field strengths (Fig. 1). Slice Encoding for ...

متن کامل

Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images

PURPOSE To compare short tau inversion recovery (STIR) images with slice encoding for metal artifact correction (SEMAC)-corrected magnetic resonance imaging (MRI) of spectral presaturation with inversion recovery (SPIR) or inversion recovery (IR) at 3T in patients with metallic spinal instrumentation. METHODS Following institutional review board's approval, 71 vertebrae with interbody fixatio...

متن کامل

Optimization of Scan Time in MRI for Total Hip Prostheses: SEMAC Tailoring for Prosthetic Implants Containing Different Types of Metals.

INTRODUCTION Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally,...

متن کامل

View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application

BACKGROUND MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts. PURPOSES To evaluate the benefit of view-angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) for MRI of large-sized orthopaedic tumor endoprostheses in a...

متن کامل

Noise Considerations in Slice Encoding for Metal Artifact Correction

Fig. 2: Illustration of the correction of throughplane distortions. The SEMAC sequence excites multiple slices with no gap in between and resolves the arbitrary distorted excitation slice profiles with the additional z-phase encoding. The correction is done by combining the signals resolved from different slices at each voxel, but many of which only contain background noise. Noise Consideration...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 62 1  شماره 

صفحات  -

تاریخ انتشار 2009