Gas-chromatographic determination of ethanol in blood with 0.53-mm fused-silica open tubular columns.

نویسنده

  • Z Penton
چکیده

Several 0.53 mm (i.d.) fused-silica open tubular columns were evaluated for the gas-chromatographic determination of ethanol and other volatiles in blood by both headspace and liquid injection. These columns offer the advantages of fused-silica technology without requiring expensive modification of the instrument for capillary. Methyl silicone columns of various lengths and film thicknesses were examined and also a polyethylene glycol column. The merits of each column are discussed and relative retention times are given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bonded Polymethacrylate Stationary Phases for Open Tubular Liquid Chromatographic and Electrochromatographic Separations

Using a new procedure developed in our laboratory for the preparation of thick polymethacrylate films bonded in fused silica capillaries, crosslinked polymeric stationary phases were synthesized in situ in 25-mm-i.d. capillaries. The effect of monomer and crosslinker concentrations on the resulting polymer film Ž . was studied by open tubular capillary electrokinetic chromatography OTCEC Ž . us...

متن کامل

Silver-StainedPhenotypingof a1-Antitrypsinin DriedBloodand Serum Specimens

CLIN. CHEM. 30/10, 1874-1a76 (1984) phy. J High Resolution Chromatogr Chromatogr Commun 5,377378 (1982). 3. LiebichHM, BuelowJJ, Kallmayer B..Quantification ofendogenousaliphatic alcohols in serum and urine. J Chromatogr 239,343349 (1982). 4. Doizaki WM, Levitt MD. Gas chromatographic method for the determination of the lower volatile alcoholsin rat blood and in human stool specimens on a fused...

متن کامل

Trace Level Determination of Mesityl Oxide and Diacetone Alcohol in Atazanavir Sulfate Drug Substance by a Gas Chromatography Method.

A capillary gas chromatography method with a short run time, using a flame ionization detector, has been developed for the quantitative determination of trace level analysis of mesityl oxide and diacetone alcohol in the atazanavir sulfate drug substance. The chromatographic method was achieved on a fused silica capillary column coated with 5% diphenyl and 95% dimethyl polysiloxane stationary ph...

متن کامل

Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS)

Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantag...

متن کامل

Polyimide polymer glass-free capillary columns for gas chromatography.

Polymeric polyimide capillary tubing, both uncoated and coated with stationary phases of two polarities, is explored for use as capillary columns for gas chromatography (GC). These glass-free polyimide columns are flexible and their small winding diameter of less than a cm around a solid support makes them compatible for potential use in portable GC instruments. Polyimide columns with dimension...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 1987