Implant stability evaluation by resonance frequency analysis in the fit lock technique. A clinical study.
نویسندگان
چکیده
Surgical procedures for the application of implants in the lateral-superior sectors are affected by the availability of the residual bone. When this condition is lower than 5 mm it is recommended that techniques involving two therapeutic phases, a reconstructive and an applicative one, as reported in the international literature, are adopted. The authors propose here a new method with the potential to apply implants simultaneously with the reconstructive phase. The aim of this longitudinal retrospective study was to evaluate the stability of implants applied with the fit lock technique in the upper maxillarys in us with bone availability lower than 4 mm by measuring resonance frequency at different follow-up periods The seme as urements, carried out on 30 implants, were analysed with specific statistical procedures. The results indicate that the stability of the implants inserted with the fit lock method increases progressively over time in a statistically significant manner. The stability recorded after one year from the insertion (ISQ T2) is significantly higher than that recorded after six months (ISQ T1), and this is significantly higher than that recorded at the time of implant placement (ISQ T0). The implants inserted in the maxillary zones with scarce bone availability and applied with this technique showed a similar stability as reported with other techniques. In light of the results, the authors confirm that the primary stability represents the basic requirement to guarantee a correct healing of the implant and demonstrate that the fit lock technique also all ows reaching this condition when bone availability is minimal.
منابع مشابه
Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملBiomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis
BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remain...
متن کاملThe Influence of Site Preparation (Countersinking) on Initial Dental Implant Stability. An in vitro Study Using Resonance Frequency Analysis
Primary implant stability is considered to be a critical factor for obtaining successful osseointegration [1]. Studies using Resonance Frequency Analysis (RFA) have demonstrated that initial implant stability is determined by the density of the bone, the surgical technique used, and the design of the implant [2, 3]. While different implant designs have shown similar results of higher stabilitie...
متن کاملClinical evaluation of osseointegration using resonance frequency analysis
The stability of the implant at the time of placement and during the development of the osseointegration process are the two major issues governing the implant survival. Implant stability is a mechanical phenomenon related to local factors such as bone quality, quantity, type of placement technique and type of implant used. The application of a user-friendly, clinically reliable, non-invasive m...
متن کاملEffect of bone quality and implant surgical technique on implant stability quotient (ISQ) value
PURPOSE This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS Two different types of bone (type 1 and type 2) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annali di stomatologia
دوره 4 2 شماره
صفحات -
تاریخ انتشار 2013