Feasibility Study and Installation of Thermal Neutron Driven 14 MeV Neutron Converter into the TRIGA Research Reactor
نویسندگان
چکیده
Tentative design and implementation of an irradiation facility are described, which will add a 14 MeV component to the neutron spectrum in a thermal research reactor irradiation facility. The idea is to exploit the Li(n,T)He reaction in a blanket of lithium in a deuterated environment, placed in a thermal reactor irradiation channel. Existing literature describing similar devices is reviewed, theoretical basis is presented and plans for the design and implementation are described. Potential uses of such a device are activation studies of new materials developed for fusion reactors like ITER and DEMO, evaluated nuclear reaction data validation at energies above 10 MeV, fast neutron activation analysis, etc.
منابع مشابه
Feasibility of the Prompt Gamma Activation Analysis Facility at Triga Ipr-r1 Reactor in Brazil
This work presents the preliminary design of a PGNAA (Prompt Gamma Neutron Activation Analysis) facility at the TRIGA IPR-R1 research reactor of the CDTN. The results of experimental and calculated neutron flux in a vertical tube are presented and discussed. The results confirm the technical feasibility of the installation of PGNAA at the TRIGA reactor and the possibility of enhancing the appli...
متن کاملProposed design for the PGAA facility at the TRIGA IPR-R1 research reactor
BACKGROUND This work presents an initial proposed design of a Prompt Gamma Activation Analysis (PGAA) facility to be installed at the TRIGA IPR-R1, a 60 years old research reactor of the Centre of Development of Nuclear Technology (CDTN) in Brazil. The basic characteristics of the facility and the results of the neutron flux are presented and discussed. FINDINGS The proposed design is based o...
متن کاملبهینهسازی پاسخ دزیمتری نوترون در بازه انرژی حرارتی و سریع برای آشکارساز دیودی
During the last few years, real time gamma and neutron dosimeters have been developed and semiconductor diodes are frequently used in these dosimeters. Semiconductor diodes are used to charged particle detection. For sensitizing the detector to neutrons, a converter layer is contacted on the front surfaces of them. Incident neutrons interact with the converter and produce charged particles that...
متن کاملModeling a TRIGA Mark II Biological Shield using MCNP5
The 250kW TRIGA Mark II research reactor, Vienna, is equipped with experimental facilities inside and outside the reactor core. Outside the core, there are four beam tubes (three radial and one tangential beam tube), a thermal column and a neutron radiography collimator, supplying neutrons for irradiation experiments. These experiments include neutron radiography, neutron tomography, neutron ac...
متن کاملCharacterization of a Neutron Collimator for Neutron Radiography
At the ENEA TRIGA research reactor (Casaccia Research Center, Rome), a new neutron collimator has been designed and installed at the neutron tangential channel. This collimator, that is part of a neutron/X-ray facility for NDT analysis, was experimentally characterized and optimized in terms of thermal neutron flux, its spatial/energetic distribution, photon air KERMA and effective beam diamete...
متن کامل