Stable Baseline Correction of Digital Strong-Motion Data
نویسنده
چکیده
Most baseline errors of analog strong-motion data still exist in highresolution data. In this study, we identify the major baseline errors of digital strong-motion data and propose a three-step algorithm to correct these errors. The major baseline errors found in these digital data consist of constant drift in the acceleration, low-frequency instrument noise, low-frequency background noise, the small initial values for acceleration and velocity, and manipulation errors. This threestep algorithm includes fitting the baseline of acceleration by the least squares, applying a high-pass filter in acceleration, and subtracting the initial values in velocity. A least-squares fit of a straight line before filtering can effectively remove the baseline drift in acceleration. Then, the filtering removes the linear trend and other low-frequency errors that exist in the acceleration. Finally, the subtracting of the initial velocity removes the linear trend of displacement. Among these three steps, only the filtering in the second step may introduce a side effect. Compared to the Volume II routine developed by Trifunac and Lee (1973), this three-step processing significantly reduces computational efforts and side effects resulting from unnecessary manipulation of data. This algorithm has been successfully tested on several types of digital strong-motion data. Several independent validations show that the proposed algorithm is stable.
منابع مشابه
Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملاصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملDetermining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels
Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...
متن کاملOptimal fast digital error correction method of pipelined analog to digital converter with DLMS algorithm
In this paper, convergence rate of digital error correction algorithm in correction of capacitor mismatch error and finite and nonlinear gain of Op-Amp has increased significantly by the use of DLMS, an evolutionary search algorithm. To this end, a 16-bit pipelined analog to digital converter was modeled. The obtained digital model is a FIR filter with 16 adjustable weights. To adjust weights o...
متن کامل