Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting.

نویسندگان

  • P D Bridge
  • S Ranganathan
  • S A McKenzie
چکیده

This study describes the feasibility, repeatability, and interrater reliability of the measurement of airway resistance by the interrupter technique (Rint) in children 2-5 yrs of age, and examines whether reversibility to bronchodilator can be demonstrated in wheezy children. The mean of six Rint values was taken as a measurement. If subjects could complete one measurement and then a second 15 min after bronchodilator, baseline testing and reversibility testing were considered feasible. To measure repeatability, two measurements 30 s apart and measurements before and 15 min after placebo bronchodilator were compared. Measurements by two testers were compared for interrater reliability. Change in Rint in wheezy children was measured after bronchodilator. Fifty-six per cent of 2-3-yr-olds (n=79), 81% of 3-4-yr-olds (n=104) and 95% of 4-5-yr-olds (n=88) completed baseline testing, and 53%, 71% and 91% completed reversibility testing. Baseline measurements were 0.47-2.56 kPa x L(-1) x s. Repeatabilities (2 SD of the mean differences between measurements) at 30 s in the three age bands were 0.21, 0.17 and 0.15 kPa x L(-1) x s and 0.19 kPa x L(-1) x s after placebo. Using 0.21 kPa x L(-1) x s as the threshold for reversibility, reversibility was demonstrated in most wheezy children. Interrater reliability was 0.15 kPa x L(-1) x s. Preschool children can undertake measurements of airway resistance by the interrupter technique in ambulatory settings and reversibility to bronchodilator in wheezy children can be demonstrated. This technique promises to be a useful clinical and research tool.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airway resistance and atopy in preschool children with wheeze and cough.

The extent to which the measurement of airways resistance by the interrupter technique (Rint) distinguishes preschool children with previous wheeze from those with no respiratory symptoms and helps to classify subjects with persistent cough, was investigated. Rint was measured before and after salbutamol treatment in 82 children with recurrent wheeze, 58 with isolated cough and 48 with no sympt...

متن کامل

A portable device based on the interrupter technique for measuring airway resistance in preschool children.

The interrupter technique for measuring airway resistance is a noninvasive method reported to require minimal subject cooperation. Therefore it has a good potential for use in young children who are not able to cooperate with conventional lung function tests. The interrupter method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equil...

متن کامل

Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities.

BACKGROUND AND AIMS The measurement of airway resistance using the interrupter technique (R(int)) is feasible in preschool children and other subjects unable to undertake spirometry. This makes it potentially useful for the measurement of lung function in these groups. Commercial devices use different algorithms to measure pressure and flow from which R(int) is derived. This study provides norm...

متن کامل

Lung Function Tests in Preschool Children.

The measurement of lung function by spirometry is routinely used to monitor and adequately treat children with asthma. The assessment and evaluation of lung function in children aged 3-5 years has been neglected for a long time because of the difficulty to perform forced expiratory maneuvers. However, the use of techniques such as the interrupter technique and the forced oscillation technique, ...

متن کامل

Evaluation of a new interrupter device for measuring bronchial responsiveness and the response to bronchodilator in 3 year old children.

The interrupter technique for measuring airway resistance is non-invasive and convenient, and therefore ideally suited for the assessment of induced changes in airway calibre in preschool children. The aim of this study was to evaluate a commercially available interrupter device (based on Microlab 4000), which calculates the interrupter resistance (Rint) from pressure and flow following a brief...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 1999