Effect of stem length on prosthetic radial head micromotion.

نویسندگان

  • Dave R Shukla
  • James S Fitzsimmons
  • Kai-Nan An
  • Shawn W O'Driscoll
چکیده

BACKGROUND Osteointegration of press-fit radial head implants is achieved by limiting micromotion between the stem and bone. Aspects of stem design that contribute to the enhancement of initial stability (ie, stem diameter and surface coating) have been investigated. The importance of total prosthesis length and level of the neck cut has not been examined. METHODS Cadaveric radii were implanted with cementless, porous-coated radial head stems. We resected 10, 12, 15, 20, and 25 mm of radial neck in each specimen. Stem-bone micromotion was measured after each cut. Values were expressed in terms of quotients (cantilever quotient). RESULTS A threshold effect was observed at 15 mm of neck resection (cantilever quotient, 0.4), with a significant increase in micromotion observed between 12 mm (40 ± 10 μm) and 15 mm (80 ± 25 μm). A cantilever quotient of 0.35 or less predicted implant stability, whereas implants with a cantilever quotient of 0.6 or more were unstable. In between, the stems were "at risk" of instability. CONCLUSION Initial stem stability of a porous-coated, cementless radial head implant is dependent on length of the implant stem within bone and the level of the cut (amount of bone resected). Stability may be compromised by an implant with a combined head and neck length that is too long compared with the stem length within the canal. We found a critical ratio of exposed prosthesis to total implant length (cantilever quotient of 0.4), which puts the prosthesis at risk of inadequate initial stability. These data carry important implications for implant design and use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Outcomes after Primary Radial Head Resection Arthroplasty vs. Acute Radial Head Resection vs. Secondary Prosthetic Removal in Comminuted Radial Head Fractures

Background: Aim of this study was to compare the clinical and radiological long-term outcomes following operativetreatment of comminuted radial head fractures using 1) primary radial head resection arthroplasty, 2) acute radial headresection, or 3) necessary secondary prosthetic removal. Additionally, we evaluated complex radial head fracturescombined with elbow dislocation and verified the hyp...

متن کامل

Failure of a Unipolar Radial Head Prosthesis Due to Component Dissociation.

Radial head implant arthroplasty is a consideration for the treatment of comminuted, unreconstructable fractures of the radial head. Many prosthetic designs exist and can be unipolar or bipolar, each of which can be cemented or noncemented. For most unipolar designs, a prosthetic stem is first implanted into the proximal radius. The prosthetic radial head is then impacted onto a morse taper on ...

متن کامل

2-year follow-up report on micromotion of a short tibia stem

BACKGROUND AND PURPOSE A shortened tibial stem could influence the early prosthetic fixation. We therefore compared the short stem to the standard-length stem using radiostereometric analysis (RSA) as primary outcome measure. PATIENTS AND METHODS 60 patients were randomized to receive a cemented Triathlon total knee arthroplasty (TKA) with a tibial tray of either standard or short stem length...

متن کامل

Upper limb Laxity of the elbow after experimental excision of the radial head and division of the medial collateral ligament EFFICACY OF LIGAMENT REPAIR AND RADIAL HEAD PROSTHETIC REPLACEMENT: A CADAVER STUDY

©2003 British Editorial Society of Bone and Joint Surgery doi:10.1302/0301-620X.85B7.14405 $2.00 e studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five cadaver elbows. Division of the MCL increased valgus angulation (mean 3.9 ± 1.5 ̊) and internal rotatory la...

متن کامل

Micromotion-induced peri-prosthetic fluid flow around a cementless femoral stem.

Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2012