The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments
نویسندگان
چکیده
OBJECTIVE The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. MATERIAL AND METHODS Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. RESULTS WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. CONCLUSION After clinical use, no statistically significant reduction in the torsional resistance was observed.
منابع مشابه
Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne.
INTRODUCTION The use of reciprocating movement was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison with continuous rotation. Recently 2 new brands of NiTi files have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these 2 files, Reciproc and WaveOne. METHODS Cyclic...
متن کاملCyclic fatigue and torsional resistance of two new nickel - titanium instruments used in reciprocation motion : Reciproc Versus
The use of reciprocating movement (RM) was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison to continuous rotation (CR). Recently two new brands of NiTi file have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these two files; Reciproc and WaveOne. Cyclic fatigue tes...
متن کاملCyclic fatigue of Reciproc and WaveOne reciprocating instruments.
AIM To evaluate the cyclic fatigue resistance of Reciproc(®) and WaveOne(®) instruments in simulated root canals. METHODOLOGY Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc(®) R25 and group B: WaveOne(®) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instrument's ...
متن کاملCutting efficiency of Reciproc and waveOne reciprocating instruments.
INTRODUCTION The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne. METHODS Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated b...
متن کاملComparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...
متن کامل