Energy Conservation and the Promotion of Legionella pneumophila Growth: The Probable Role of Heat Exchangers in a Nosocomial Outbreak

نویسندگان

  • Emilie Bédard
  • Simon Lévesque
  • Philippe Martin
  • Linda Pinsonneault
  • Kiran Paranjape
  • Cindy Lalancette
  • Charles-Éric Dolcé
  • Manuela Villion
  • Louis Valiquette
  • Sébastien P. Faucher
  • Michèle Prévost
چکیده

OBJECTIVE To determine the source of a Legionella pneumophila serogroup 5 nosocomial outbreak and the role of the heat exchanger installed on the hot water system within the previous year. SETTING A 400-bed tertiary care university hospital in Sherbrooke, Canada. METHODS Hot water samples were collected and cultured for L. pneumophila from 25 taps (baths and sinks) within wing A and 9 taps in wing B. Biofilm (5) and 2 L water samples (3) were collected within the heat exchangers for L. pneumophila culture and detection of protists. Sequence-based typing was performed on strain DNA extracts and pulsed-field gel electrophoresis patterns were analyzed. RESULTS Following 2 cases of hospital-acquired legionellosis, the hot water system investigation revealed a large proportion of L. pneumophila serogroup 5 positive taps (22/25 in wing A and 5/9 in wing B). High positivity was also detected in the heat exchanger of wing A in water samples (3/3) and swabs from the heat exchanger (4/5). The outbreak genotyping investigation identified the hot water system as the source of infections. Genotyping results revealed that all isolated environmental strains harbored the same related pulsed-field gel electrophoresis pattern and sequence-based type. CONCLUSIONS Two cases of hospital-acquired legionellosis occurred in the year following the installation of a heat exchanger to preheat hospital hot water. No cases were reported previously, although the same L. pneumophila strain was isolated from the hot water system in 1995. The heat exchanger promoted L. pneumophila growth and may have contributed to confirmed clinical cases. Infect. Control Hosp. Epidemiol. 2016;1475-1480.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Energy Conservation Potential of the Heat Pipe Heat Exchangers: Experimental Study and Predictions

The energy conservation potential of the heat pipe based heat exchangers (HPHXs) was studied in this research. To this end, a typical climate chamber as the representative of an air conditioning system was established. The performance characteristic of a typical eight-row HPHX was obtained based on the one week operation (168 h) to determine the performance characteristic curves. The coil face ...

متن کامل

An Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran

Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...

متن کامل

The Different Antibacterial Impact of Silver Nanoparticles Against Legionella pneumophila Compared to Other Microorganisms

Legionella pneumophila is the pathogen responsible for severe pneumonia known as Legionnaires’ disease. Legionella can live under varied stress conditions, especially in cold environments, and is common in many artificial environments. In this study, the antimicrobial activity of biogenic silver nanoparticles, prepared using the culture supernatant of Klebsiella pneumoniae, was evaluated agains...

متن کامل

فراوانی لژیونلا پنوموفیلا در شیر آب سرد و گرم و مخزن آب انکوباتورهای بخش نوزادان بیمارستانهای گیلان

Background and purpose: Nosocomial outbreaks of legionnaires’ diseases are usually related to contamination of water sources. This survey investigated the frequency of mip gene in cold and warm water taps and water containers of infant incubators containing legionella pneumophila in hospitals of Guilan province, Iran. Materials and methods: This cross-sectional study used 140 samples. They wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2016