Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.
نویسندگان
چکیده
Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varying nature. In this work we describe the effects of undesirable gradient performance on SI. Measurements of the true readout trajectories were performed and the results were then used in the reconstruction process. The effects of these imperfections resulted in a spatially and spectrally varying amplitude and frequency modulation. The use of the measured trajectories in the reconstruction process yielded an up to 20% increase in signal amplitude recovery.
منابع مشابه
Gradient moment compensated magnetic resonance spectroscopic imaging.
Spectroscopic imaging applications outside of the brain can suffer from artifacts due to inherent long scan times and susceptibility to motion. A fast spectroscopic imaging sequence has been devised with reduced sensitivity to motion. The sequence uses oscillating readout gradients and acquires k-space data in a spiral out-in fashion, which allows fast k-space coverage. We show that a spiral ou...
متن کاملSimple correction method for k-space trajectory deviations in MRI.
A method is presented to correct for the imperfections of spatial encoding gradients in MRI. The approach is simple and fast, can be performed with standard scanner hardware, and does not require separate measurements with reference phantoms. The new method, using the MR signal to accurately measure the k-space trajectory of the imaging sequence, allows for correction of gradient hardware imper...
متن کاملTruncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.
Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating signals of metabolites therein. This work presents a data acquisition strategy ...
متن کاملFast Magnetic Resonance Spectroscopic Imaging Using RF Coil Arrays
Conventional Magnetic Resonance Spectroscopic Imaging (MRSI) suffers from both low signal-to-noise (SNR), as well as long acquisition times. The development of high-fidelity gradient coils has opened opportunities for fast k-space encoding schemes that are already used in structural imaging. At the same time, receive-coil arrays using 4 and 23 channels have been developed and reported to produc...
متن کاملSpiral imaging in fMRI
T2*-weighted Blood Oxygen Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) requires efficient acquisition methods in order to fully sample the brain in a several second time period. The most widely used approach is Echo Planar Imaging (EPI), which utilizes a Cartesian trajectory to cover k-space. This trajectory is subject to ghosts from off-resonance and gradient imperfectio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2006