2.4kW Unity Power Factor Rectifier

نویسنده

  • Matthew Douglas
چکیده

work submitted in this thesis is my own work, except as acknowledged in the text, and has not previously been submitted for a degree at the University of Queensland or any other institution. Acknowledgements I would like to thank the following people for their valuable assistance during the year: Dr Geoff Walker, for his supervision and on his ongoing assistance throughout the year. His willingness to be a mentor, to engage in problem solving and to provide feedback was greatly appreciated and valued. Keith Bell, for his assistance in fabricating PCBs in an efficient and positive manner. Abstract The goal of this thesis is to develop a 2.4kW unity power factor rectifier. The final product will operate at an input of 240V and 10A. The motive for the development of this product was to develop a power supply capable of forming the basis for a battery charger. The Sustainable Energy Research Group (SERG) are currently developing a hybrid electric/solar car and it is hoped a battery charged can be developed to allow fast overnight charging of the 100 lithium ion cells which make up the battery pack. Worldwide AC/DC switch mode power supplies (SMPS) are a multi billion dollar industry and continues to be a growth industry within the field of power electronics. SMPS service applications range from communication and computers through to military uses. One of the leading topics in line-operated power-converter design is to take the power from the grid but not to return it. Ideally, the power converter will present as purely resistive to the ac source. This is known as Unity Power Factor (UPF) and it has become an important design issue as a consequence of recent legislation. European legislation restricts the harmonic content for power supplies. International standards are emerging known as the IEC 1000

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unity Power Factor Control by Pwm Rectifier

Abstract This paper analyzes the principle of PWM rectifier and presents a unity power factor control method of PWM rectifier. Controller used double closed-loop PI control, which inner uses three-phase input current control method controlled by unity power factor and outer controls the output DC voltage of rectifier. Voltage phase detection methods which proposed could eliminate the affection ...

متن کامل

Fast Controller for a Unity-Power-Factor PWM Rectifier - Power Electronics, IEEE Transactions on

This paper presents an analog implementation of a fast controller for a unity-power-factor (UPF) PWM rectifier. The best settling times of many popular controllers for this type of converter are on the order of a few line cycles, corresponding to bandwidths under 20 Hz [l]. The fast controller demonstrated in this paper can exercise control action at a rate comparable to the switching frequency...

متن کامل

Implementation of Low-Cost Architecture for Control an Active Front End Rectifier

In AC-DC power conversion, active front end rectifiers offer several advantages over diode rectifiers such as bidirectional power flow capability, sinusoidal input currents and controllable power factor. A digital finite control set model predictive controller based on fixed-point computations of an active front end rectifier with unity displacement of input voltage and current to improve dynam...

متن کامل

Buck-Boost-Type Unity Power Factor Rectifier With Extended Voltage Conversion Ratio

A buck–boost-type unity power factor rectifier is proposed in this paper. The main advantage of the proposed rectifier over the conventional buck–boost type is that it can perform input power factor correction (PFC) over a wider voltage conversion range. With a single switch, a fast well-regulated output voltage is achieved with a zero-current switch at turn-on. Moreover, the switch voltage str...

متن کامل

Evaluation of a Delta-Connection of Three Single-Phase Unity Power Factor Rectifier Modules ( -Rectifier) in Comparison to a Direct Three-Phase Rectifier Realization Part II – Component Stress Evaluation, Efficiency, Control

In this paper the voltage and current stress of a delta-connection of three single-phase boost-type unity power factor rectifier modules ( -Rectifier) is analyzed in order to perform a design comparable to a direct threephase three-level six-switch unity power factor (conventional) rectifier system. The conduction losses of the power semiconductors are calculated using analytical approximations...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003